The Actual Efficacy of an Air Purifier at Different Outdoor PM2.5 Concentrations in Residential Houses with Different Airtightness

Author:

Shin Dongho,Kim YounghunORCID,Hong Keejung,Lee Gunhee,Park Inyong,Han Bangwoo

Abstract

It is important to control airborne particles in residential houses for protecting human health. Indoor particulate matter of <2.5 μm (PM2.5) can be effectively monitored and managed using an air purifier. In this study, the actual clean air delivery rates in residential houses (CADRActual) were acquired by comparing decay rates of fine particles with and without operations of the air purifier under actual conditions, following the standard CADR of an air purifier obtained in a closed test chamber. The measurements of CADRActual at different outdoor PM2.5 concentrations over a month in two residential houses revealed different airtightness levels, compared to the standardized clean air delivery rate of the air purifier (CADRAP). Air changes per hour at 50 Pa (ACH50) was 4.8 h−1 for “house A” (built in 2007) and 2.1 h−1 for “house B” (built in 2018). The CADR of the air purifier used in this study was 10.6 m3/min, while the averaged CADRActual at the “house A” was 7.2 m3/min (approximately 66% of the CADR of the air purifier) and 9.5 m3/min at “house B” (approximately 90% of the CADR of the air purifier). Under the outdoor PM2.5 concentrations of <35 μg/m3, the averaged CADRActual of house A and house B were 7.8 ± 0.3 and 9.7 ± 0.4 m3/min, respectively. However, under the outdoor PM2.5 concentrations of >35 μg/m3, the analogous averaged concentrations were 6.8 ± 0.6 and 9.6 ± 0.3 m3/min for houses A and B, respectively. The measured CADRActual agreed well with the theoretical estimates of CADRActual acquired by the mass balance equation using the infiltration rate of ACH50/20. We also estimated CADRActual/CADRAP for house C built in 2017, where the ACH50 was 1.8 h−1. Overall, this study demonstrated how CADRActual/CADRAP of an air purifier at residential houses can be predicted according to outdoor PM2.5 concentration and airtightness of the house. As shown, it can be closer to 1 at lower ACH50 houses and at lower outdoor PM2.5 concentrations.

Funder

Korea Institute of Machinery and Materials

Publisher

MDPI AG

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3