Determination of 19 Steroid Hormones in Human Serum and Urine Using Liquid Chromatography-Tandem Mass Spectrometry

Author:

Li Zhong-MinORCID,Kannan Kurunthachalam

Abstract

This paper describes a methodology for simultaneous determination of 19 steroid hormones, viz. estrone, estradiol, estriol, testosterone, 5α-dihydrotestosterone, androstenedione, androstenediol, dehydroepiandrosterone, progesterone, pregnenolone, 17α-OH-progesterone, 17α-OH-pregnenolone, cortisone, cortisol, 11-deoxycortisol, 11-deoxycorticosterone, 11-dehydrocorticosterone, aldosterone, and corticosterone, in 500-µL of urine or serum/plasma. The method was optimized using isotopically labeled internal standards and liquid-liquid extraction followed by detection using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS). Dansylation of estrogens significantly improved their sensitivities (~11- to 23-fold) and chromatographic separation. The respective limit of detection (LOD) and limit of quantification (LOQ) of all analytes were 0.04–0.28 and 0.14–0.92 ng/mL in human urine, and 0.11–0.35 and 0.38–1.18 ng/mL in human serum/plasma. Recoveries of all analytes (except for progesterone) fortified at 10, 20, and 200 ng/mL in urine and serum were 80–120%, with standard deviations ranging from 0 to 17.3%. Repeated analysis of similarly fortified urine and serum samples yielded intra-day and inter-day variations of 0–21.7% and 0.16–11.5%, respectively. All analytes except cortisone exhibited weak matrix effects in urine and serum (−13.9–18.2%). The method was further validated through the analysis of the National Institute of Standards and Technology (NIST) plasma Standard Reference Material (SRM1950) with certified concentrations for cortisol, progesterone, and testosterone (coefficient of variation: 3–11%). The developed method was applied in the analysis of urine samples from 20 volunteers, which revealed the occurrence of 16 analytes with detection frequencies (DFs) > 80%. Furthermore, 15 analytes were found in plasma SRM1950, indicating the feasibility of our method in the analysis of steroid hormones in urine and serum/plasma. This method will facilitate analysis of steroid hormones in population-based biomonitoring studies.

Funder

National Institute of Environmental Health Sciences

Publisher

MDPI AG

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology

Reference27 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3