Abstract
Flexural strength (FS) and translucency (Contrast Ratio-CR) of three different factory crystallized silica-based glass ceramics, Celtra Duo (CD), N!ce (NI) and Li-Si Block, a lithium disilicate, IPS e.max CAD (LD), and a leucite-reinforced feldspathic ceramic, Empress CAD (EM), in two different translucencies (HT and LT) for use in chairside dental restorations have been compared. CAD blocks of the materials were cut into beams and tiles and processed following manufacturers’ instructions. The beams were tested (3-PBT) to determine flexural strength, Weibull characteristic strength, and Weibull modulus; and tiles were tested to determine CR. All data were statistically analyzed. In addition, SEM analysis of the materials was performed. Differences in flexural strength (FS) and translucency (CR) between the materials were found to be statistically significant. FS decreased as follows (MPa): LDHT 350.88 ± 19.77 (a) = LDLT 343.57 ± 18.48 (a) > LSLT 202.15 ± 17.41 (b) = LSHT 196.93 ± 8.87 > NIHT 186.69 ± 13.06 (c) = CDLT 184.73 ± 13.63 (c) = CDHT 174.15 ± 21.76 (c) = NILT 172.12 ± 11.98 (c) > EMHT 131.16 ± 13.33 (e) = EMLT 127.65 ± 11.09. CR decreased as follows (mean ± sd): CDLT 74.1 ± 1.1 (a); LSLT 74.0 ± 1.1 (ab); NILT 73.3 ± 0.8 (ab); EMLT 73.0 ± 1.5 (ab); NIHT 72.4 ± 1.0 (bc); LDLT 71.3 ± 1.1 (bc); LTHT 65.2 ± 0.9 (de); LSHT 63.8 ± 1.1 (def); EMHT 636 ± 1.2 (ef); CDHT 62.2 ± 0.8 (f). Our findings show that factory-crystallized lithium silicate glass ceramics fulfill ISO standards for Classes 1 and 2. Therefore, they can be considered viable alternatives to produce single-unit restorations with a chairside procedure not requiring thermal treatment.
Subject
General Materials Science
Reference36 articles.
1. Baldi, A., Comba, A., Michelotto Tempesta, R., Carossa, M., Pereira, G.K.R., Valandro, L.F., Paolone, G., Vichi, A., Goracci, C., and Scotti, N. External Marginal Gap Variation and Residual Fracture Resistance of Composite and Lithium-Silicate CAD/CAM Overlays after Cyclic Fatigue over Endodontically-Treated Molars. Polymers, 2021. 13.
2. External gap progression after cyclic fatigue of adhesive overlays and crowns made with high translucency zirconia or lithium silicate;Baldi;J. Esthet. Restor. Dent.,2022
3. An overview of the CEREC 3D CAD/CAM system;Allen;Gen. Dent.,2004
4. A review of dental CAD/ CAM: Current status and future perspectives from 20 years of experience;Miyazaki;Dent. Mater. J.,2009
5. Clinical performance of chairside CAD/CAM restorations;Fasbinder;J. Am. Dent. Assoc.,2006
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献