Abstract
Due to the high strength-to-weight ratio of fibre reinforced polymers (FRPs), human-induced vibration problematic remains as a subject to be fully comprehended in order to extend the use of composites in Bridge Engineering. Thus, this paper studies an ultra-lightweight FRP footbridge, which presents excessive vertical vibrations when the fourth harmonic of a walking pedestrian is synchronised with the structure’s fundamental frequency. Focusing on the vertical bending mode, at 7.66 Hz, the bridge dynamic behaviour was assessed under the action of a single pedestrian crossing the facility at a step frequency of 1.9 Hz. As an over prediction of the footbridge response was computed using a moving force (MF) model available in a design guideline, a mass-spring-damper-actuator (MSDA) system was adopted to depict a walker. Hence, Human-Structure Interaction (HSI) phenomenon was considered. Employing the experimental results, parameters of the MSDA system were identified, leading to a HSI model that considers the first fourth harmonics of a walking human. Additionally, a parametric analysis was carried out, determining that the damping ratio of the human body and the load factor associated to the fourth harmonic are the most relevant parameters on the estimation of the response. The identified HSI model may be used as a first approximation to accurately predict the dynamic response of ultra-lightweight composite structures and should be extended to account for crowd-induced loads.
Funder
Ministry of Science, Innovation and Universities of Spain
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献