Author:
Wang Yazhou,Cai Xin,Lin Shifa,Xu Bofeng,Zhang Yuan,Bian Saixian
Abstract
Large-scale wind turbines often face the problem of tower clearance safety under extreme gust conditions. Since gust intensity is positively correlated with the change rate of the generator’s speed, a gust identification method is proposed based on wind turbine monitoring data. Furthermore, a novel tower clearance safety protection strategy is proposed, which superimposes some additional speed requirements on the basis of normal pitch rate when identifying extreme gust so as to alleviate the dynamic response of the wind turbine. Simulations and comparison of a 5 MW wind turbine, before and after applying the new strategy, showed that the new strategy can induce an increase in pitch angle for the wind turbine and, simultaneously, avoids the emergency stop caused by the generator’s overspeed. Meanwhile, when the new strategy is adopted, the blade tip’s deformation and the load on the top of the tower are reduced by 19.9% and 52.2%, respectively. Therefore, the proposed strategy can not only protect the safety of the wind turbine but it also reduces costs.
Funder
Supported by the Fundamental Research Funds for the Central Universities
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献