The Forces Associated with Bolus Injection and Continuous Infusion Techniques during Ultrasound-Targeted Nerve Contact: An Ex Vivo Study

Author:

Agweder Ashraf1,Zeng Youheng1,Liu Jiatao1,McLeod Graeme23ORCID,Huang Zhihong1

Affiliation:

1. School of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK

2. School of Medicine, University of Dundee, Dundee DD2 1SY, UK

3. Ninewells Hospital, NHS Tayside, Dundee DD2 1SY, UK

Abstract

Ultrasound-guided regional anaesthesia with real-time visualization of anatomical structures and needle trajectory has become the standard method for accurately achieving nerve block procedures. Nevertheless, ultrasound is particularly limited in accurately detecting the needle tip in tissues with complex echogenicity. Fat-filled circumneural fascial tissue provides a barrier to local anaesthetic diffusion. Injection during gentle needle nerve contact is more likely to spread under the circumneurium (halo sign). On the other hand, excessive force may cause hematoma or activate the piezo ion channels and intraneural calcium release. Therefore, it is vital to understand the mechanics of needle–tissue interaction for optimizing the procedural outcomes and patients’ safety. We hypothesised that continuous fluid infusion would reduce the needle force applied on the nerve compared to that of bolus injection. Thus, the primary objective of this study was to compare the forces associated with the bolus injection and continuous infusion techniques on the sciatic nerves of fresh lamb legs ex vivo. A needle combining pressure and force was inserted into six legs of lambs ex vivo using a motor stage at a constant velocity and imaged with a linear transducer. Saline injections were block randomised to bolus injection or infusion in the muscle upon gently touching and indenting of the epineurium at nine sites on six sciatic nerves at three angles (30°, 45° and 60°) in each location. The bolus was delivered over 6 s and infused for over 60 s. The result showed less force was generated during the infusion technique when gently touching the epineurium than that of the bolus technique, with p = 0.004, with significant differences observed at a 60° angle (0.49 N, p = 0.001). The injection pressure was also lower when light epineurium touches were applied (9.6 kPa, p = 0.02) and at 60° (8.9 kPa). The time to peak pressure varied across the insertion angles (p < 0.001), with the shortest time at 60° (6.53 s). This study explores future applications by emphasizing the significance of understanding needle–tissue interaction mechanics. This understanding is crucial for optimizing the procedural outcomes and enhancing patients’ safety in ultrasound-guided regional anaesthesia administration. Specifically, continuous infusion demonstrated a notable reduction in needle force compared to that of the bolus injection, especially during gentle epineurium contact.

Funder

Cultural Affairs Department at the Libyan Embassy, London, UK

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3