Abstract
A technique for strengthening masonry walls by plastering with amorphous steel fiber-reinforced mortar (ASFRM) is investigated through compressive and diagonal tension tests for masonry prisms. The vertical joint between masonry units was not completely filled with mortar to mimic poor workmanship, which is typically reflected in low-cost buildings. The test variables include the number and thickness of mortar overlays, fiber volume fraction, and additional reinforcement using glass fiber mesh or shear connectors. In most strengthened specimens, the ASFRM is not damaged but separated from the masonry prisms after its maximum strength is reached. Additional tests for the bond strength between the ASFRM overlay and masonry surface are conducted to evaluate its contribution to the strengthening effects. Based on experimental observations, equations for predicting the compressive and diagonal tension strengths of masonry prisms strengthened with ASFRM are proposed. The compressive strength can be predicted more accurately by considering the asymmetrical distribution of compressive stress when strengthening is performed on only one side. The diagonal tension strength after strengthening can be predicted by incorporating the contribution of the bond strength between the ASFRM overlay and masonry prism to the initial strength.
Funder
Ministry of Land, Infrastructure and Transport
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献