Abstract
The cemento-enamel junction (CEJ) is an important reference point for various clinical measurements in oral health assessment. Identifying CEJ in ultrasound images is a challenging task for dentists. In this study, a computer-assisted detection method is proposed to identify the CEJ in ultrasound images, based on the curvature change of the junction outlining the upper edge of the enamel and cementum at the cementum–enamel intersection. The technique consists of image preprocessing steps for image enhancement, segmentation, and edge detection to locate the boundary of the enamel and cementum. The effects of the image preprocessing and the sizes of the bounding boxes enclosing the CEJ were studied. For validation, the algorithm was applied to 120 images acquired from human volunteers. The mean difference of the best performance between the proposed method and the two raters’ measurements was an average of 0.25 mm with reliability ≥ 0.98. The proposed method has the potential to assist dental professionals in CEJ identification on ultrasonographs to provide better patient care.
Funder
Alberta Innovates - Technology Futures
Mitacs
Chinese Scholarship Council
Natural Sciences and Engineering Research Council of Canada
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献