Attempt to Make the Upper-Limb Item of Objective Fugl–Meyer Assessment Using 9-Axis Motion Sensors

Author:

Ueyama Yusuke1ORCID,Takebayashi Takashi2,Takeuchi Kenta1,Yamazaki Makoto3,Hanada Keisuke4ORCID,Okita Yuho5,Shimada Shinichi6ORCID

Affiliation:

1. Department of Occupational Therapy and Rehabilitation, Itami Kousei Neurosurgical Hospital, Itami City 664-0028, Japan

2. Department of Occupational Therapy, School of Comprehensive Rehabilitation, Osaka Metropolitan University, Habikino City 558-8555, Japan

3. Department of Physical Medicine and Rehabilitation, Itami Kousei Neurosurgical Hospital, Itami City 664-0028, Japan

4. Faculty of Rehabilitation, Shijonawate Gakuen University, Daitou City 574-0011, Japan

5. Faculty of Health, Arts and Design, Swinburne University of Technology, Melbourne, VIC 3122, Australia

6. Department of Neurosurgery, Itami Kousei Neurosurgical Hospital, Itami City 664-0028, Japan

Abstract

The Fugl–Meyer Assessment (FMA) has been used as a functional assessment of upper-limb function in stroke patients. This study aimed to create a more objective and standardized evaluation based on an FMA of the upper-limb items. A total of 30 first-ever stroke patients (65.3 ± 10.3 years old) and 15 healthy participants (35.4 ± 13.4 years old) admitted to Itami Kousei Neurosurgical Hospital were included. A nine-axis motion sensor was attached to the participants, and the joint angles of 17 upper-limb items (excluding fingers) and 23 FMA upper-limb items (excluding reflexes and fingers) were measured. From the measurement results, we analyzed the time-series data of each movement and obtained the correlation between the joint angles of each part. Discriminant analysis showed that 17 and 6 items had a concordance rate of ≥80% (80.0~95.6%) and <80% (64.4~75.6%), respectively. In the multiple regression analysis of continuous variables of FMA, a good regression model was obtained to predict the FMA with three to five joint angles. The discriminant analysis for 17 evaluation items suggests the possibility of roughly calculating FMA scores from joint angles.

Funder

Teijin Pharma Limited

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference25 articles.

1. Guidelines for Adult Stroke Rehabilitation and Recovery: A Guideline for Healthcare Professionals from the American Heart Association/American Stroke Association;Winstein;Stroke,2016

2. The Post-Stroke Hemiplegic Patient. 1. A Method for Evaluation of Physical Performance;Leyman;Scand. J. Rehabil. Med.,1975

3. Outcome Measurement in Stroke: A Scale Selection Strategy;Baker;Stroke,2011

4. Platz, T., Pinkowski, C., van Wijck, F., and Johnson, G. (2005). Arm Rehabilitation Measurement: ARM; Manual for Performance and Scoring of the Fugl-Meyer Test (arm Section), Action Research Arm Test and the Box-and-Block Test, Deutscher Wissenschafts-Verlag (DWV).

5. Reliability of the Fugl-Meyer Assessment of Sensorimotor Recovery Following Cerebrovascular Accident;Duncan;Phys. Ther.,1983

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3