Screening for RV Dysfunction Using Smartphone ECG Analysis App: Validation Study with Acute Pulmonary Embolism Patients

Author:

Choi Yoo Jin1ORCID,Park Min Ji1ORCID,Cho Youngjin23ORCID,Kim Joonghee34,Lee Eunkyoung3ORCID,Son Dahyeon3ORCID,Kim Seo-Yoon1ORCID,Soh Moon Seung5ORCID

Affiliation:

1. Department of Emergency Medicine, Ajou University School of Medicine, 164, World cup-ro, Yeongtong-gu, Suwon-si 16499, Gyeonggi-do, Republic of Korea

2. Cardiovascular Center, Department of Internal Medicine, Seoul National University Bundang Hospital, 82, Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si 13620, Gyeonggi-do, Republic of Korea

3. ARPI Inc., Room 12 Startup Incubation Center, 172, Dolma-ro, Bundang-gu, Seongnam-si 13605, Gyeonggi-do, Republic of Korea

4. Department of Emergency Medicine, Seoul National University Bundang Hospital, 82, 166 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si 13620, Gyeonggi-do, Republic of Korea

5. Department of Cardiology, Ajou University School of Medicine, 164, World cup-ro, Yeongtong-gu, Suwon-si 16499, Gyeonggi-do, Republic of Korea

Abstract

Background: Acute pulmonary embolism (PE) is a critical condition where the timely and accurate assessment of right ventricular (RV) dysfunction is important for patient management. Given the limited availability of echocardiography in emergency departments (EDs), an artificial intelligence (AI) application that can identify RV dysfunction from electrocardiograms (ECGs) could improve the treatment of acute PE. Methods: This retrospective study analyzed adult acute PE patients in an ED from January 2021 to December 2023. We evaluated a smartphone application which analyzes printed ECGs to generate digital biomarkers for various conditions, including RV dysfunction (QCG-RVDys). The biomarker’s performance was compared with that of cardiologists and emergency physicians. Results: Among 116 included patients, 35 (30.2%) were diagnosed with RV dysfunction. The QCG-RVDys score demonstrated significant effectiveness in identifying RV dysfunction, with a receiver operating characteristic–area under the curve (AUC) of 0.895 (95% CI, 0.829–0.960), surpassing traditional biomarkers such as Troponin I (AUC: 0.692, 95% CI: 0.536–0.847) and ProBNP (AUC: 0.655, 95% CI: 0.532–0.778). Binarized based on the Youden Index, QCG-RVDys achieved an AUC of 0.845 (95% CI: 0.778–0.911), with a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 91.2% (95% CI: 82.4–100%), 77.8% (95% CI: 69.1–86.4%), 63.3% (95% CI: 54.4–73.9%), and 95.5% (95% CI: 90.8–100%), respectively, significantly outperforming all the expert clinicians, with their AUCs ranging from 0.628 to 0.683. Conclusions: The application demonstrates promise in rapidly assessing RV dysfunction in acute PE patients. Its high NPV could streamline patient management, potentially reducing the reliance on echocardiography in emergency settings.

Funder

Ministry of SMEs and Startups

MSIT

Technological Innovation R&D Program

NIPA

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3