Abstract
Within the framework of the project “Integrated Evaluation of Indoor Particulate Exposure”, we carried out a 4-week field study to determine indoor bioaerosol, and its contribution to particulate matter (PM)10 and organic matter. The study was carried out in university classrooms, where most of the common indoor sources of atmospheric particles are missing. Bioaerosol was determined by a method based on propidium iodide staining, observation by fluorescence microscopy, and image analysis. Indoor bioaerosol concentrations were compared with outdoor values, which were determined simultaneously. The samplings periods were scheduled to divide weekday hours, when the students were inside, from night-time hours and weekends. Very high bioaerosol concentrations were detected inside the classrooms with respect to outdoor values. The mean difference was 49 μg/m3 when the students were inside, 5.4 μg/m3 during the night, and it became negative during the weekends. Indoor-to-outdoor ratios were 6.0, 4.2, and 0.7, respectively. Bioaerosol contributed 26% to organics and 10% to PM10. In indoor samples collected during the day, the microscope images showed numerous skin fragments, which were mostly responsible for the increase in the bioaerosol mass. People’s presence proved to be responsible for a significant increase in bioaerosol concentration in crowded indoor environments.
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development
Cited by
14 articles.
订阅此论文施引文献