This paper examines the effects of different loading patterns on the static characteristics of continuous concrete beams reinforced with external prestressed carbon fiber-reinforced polymer tendons (EPCFRPT) and qualitatively analyzes the results for two continuous concrete beams: SB-1 under symmetrical loading, and SB-2 under asymmetrical loading. Then, a finite element analysis model is introduced and calibrated by tests conducted at Southeast University and data collected from a literature review. Based on the FEA model, the initial prestress, cross-section area, and eccentricity of CFRP tendons as well as the steel reinforcement configuration were selected by a parametric study. The results indicated that the initial prestress and tendon cross-section area had the most influence on the tendon stress increment and the secondary bending moment of the middle support, while the reinforcement distribution and eccentricity of the tendons had little effect. The secondary bending moment had a linear positive correlation with the stress increment of tendons. These results allow a simplified equation for calculating the external load bending moment amplitude coefficient at ultimate to be proposed.
Funder
The National Key Research and Development Program of China
Jiangsu Postdoctoral Research Foundation
Subject
General Materials Science
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献