Exhaled Breath Analysis Using Selected Ion Flow Tube Mass Spectrometry and Disease Severity in Heart Failure

Author:

Tang Wai Hong Wilson1ORCID,Tranchito Lily2,Albert Chonyang1,Gul Zeynep G.3,Cikach Frank S.1,Grove David45,Wu Yuping6,Dweik Raed A.45

Affiliation:

1. Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH 44195, USA

2. Endocrinology & Metabolism Institute, Cleveland Clinic, Cleveland, OH 44195, USA

3. Department of Surgery, Washington University School of Medicine at St Louis, St Louis, MO 63110, USA

4. Department of Inflammation and Immunology, Lerner Research Institute, Cleveland Clinic, Cleveland, OH 44195, USA

5. Respiratory Institute, Cleveland Clinic, Cleveland, OH 44195, USA

6. Department of Mathematics, Cleveland State University, Cleveland, OH 44195, USA

Abstract

Exhaled breath volatile organic compounds (VOCs) are elevated in heart failure (HF). The ability of VOCs to predict long term cardiovascular mortality and morbidity has not been independently verified. In 55 patients admitted with acute decompensated heart failure (ADHF), we measured exhaled breath acetone and pentane levels upon admission and after 48 h of diuresis. In a separate cohort of 51 cardiac patients undergoing cardiopulmonary exercise testing (CPET), we measured exhaled breath acetone and pentane levels before and at peak exercise. In the ADHF cohort, admission acetone levels correlated with lower left ventricular ejection fraction (LVEF, r = −0.297, p = 0.035). Greater weight loss with diuretic therapy correlated with a greater reduction in both acetone levels (r = −0.398, p = 0.003) and pentane levels (r = −0.309, p = 0.021). In patients with above-median weight loss (≥4.5 kg), patients demonstrated significantly greater percentage reduction in acetone (59% reduction vs. 7% increase, p < 0.001) and pentane (23% reduction vs. 2% reduction, p = 0.008). In the CPET cohort, admission acetone and pentane levels correlated with higher VE/VCO2 (r = 0.39, p = 0.005), (r = 0.035, p = 0.014). However, there were no significant correlations between baseline or peak exercise acetone and pentane levels and peak VO2. In longitudinal follow-up with a median duration of 33 months, patients with elevated exhaled acetone and pentane levels experienced higher composite adverse events of death, ventricular assist device implantation, or orthotopic heart transplantation. In patients admitted with ADHF, higher exhaled breath acetone levels are associated with lower LVEF and poorer outcomes, and greater reductions in exhaled breath acetone and pentane tracked with greater weight loss. Exhaled acetone and pentane may be novel biomarkers in heart failure worthy of future investigation.

Funder

Ohio Department of Development

National Institute of Health

Publisher

MDPI AG

Subject

Molecular Biology,Biochemistry,Endocrinology, Diabetes and Metabolism

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3