Abstract
A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.
Funder
Defense Nuclear Nonproliferation Research and Development
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference47 articles.
1. For the grid and through the grid: The role of power line communications in the smart grid;Galli;Proc. IEEE,2011
2. Local utility power line communications in the 3–500 kHz band: Channel impairments, noise, and standards;Nassar;IEEE Signal Process. Mag.,2012
3. Sonmez, M.A., Zehir, M.A., Bagriyanik, M., and Nak, O. (2013, January 20–23). Impulsive noise survey on power line communication networks up to 125 kHz for smart metering infrastructure in systems with solar inverters in Turkey. Proceedings of the 2013 International Conference on Renewable Energy Research and Applications (ICRERA), Madrid, Spain.
4. Coelho, P., Gomes, M., and Moreira, C. (2019). Microgrids Design and Implementation, Springer.
5. Realizing smart meter connectivity: Analyzing the competing technologies power line communication, mobile telephony, and radio frequency using the best worst method;Fens;Renew. Sustain. Energy Rev.,2019
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献