Effects of Blood Contamination and Decontamination Protocol on Reverse Torque Value of Abutment Screws in Dental Implants: An In Vitro Study

Author:

Adawi Hafiz A.1,Dewan Harisha1ORCID,Khawaji Arwa2,Akkam Hadeel2,Hakami Areej2,Wasli Bashair3,Hakami Maram3,Alali Maimonah3ORCID,Chohan Hitesh4

Affiliation:

1. Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

2. General Dentist, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

3. Dental Intern, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

4. Department of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

Abstract

Background and Objective: Loosening of abutment screws in dental implants is a mechanical complication that affects prosthetic treatments and hence, patient satisfaction. Blood contamination of abutment screws may play a role in this phenomenon. However, only limited research attention has been given to this issue. In the present study, we determined the effect of blood contamination and decontamination protocol on the reverse torque value (RTV) of abutment screws. Materials and Methods: A questionnaire-based survey was sent to 210 implantologists requesting feedback on their attitude to the blood contamination issue and the decontamination protocols used. The survey responses were used in a selection of the decontamination solutions that were used in the subsequent in vitro study on the effects of blood decontamination protocol on the RTV of abutment screws. Thus, three study groups were used (n = 20 abutment screws in each group): Group 1 (control group; blood-contaminated screws); Group 2 (screws decontaminated with 5.25% sodium hypochlorite (NaOCl) solution); and Group 3 (screws decontaminated with normal saline solution (0.9%)). Then, each of the connections were subjected to thermocycling, and RTVs of the screw were measured using a digital torque meter. Intragroup and intergroup RTVs were analyzed for significance using analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) tests. Results: 48% of the implantologists responded to the survey; 80% of them were concerned with blood contamination in the implant connection, especially before abutment loading and 85% of them used either chlorhexidine solution or normal saline solution as the decontamination agent. The mean RTV for Group 2 screws (30.27 ± 2.8 N.cm) was significantly greater than that for Group 3 screws (26.02 ± 1.99 N.cm) which, in turn, was significantly greater than that for Group 1 screws (23.64 ± 1.84 N.cm). Conclusion: Decontamination of blood-covered connections using 5.25% NaOCl solution or normal saline solution restores the RTV of abutment screws. This finding may have clinical relevance in that the decontaminated screws may contribute to the low incidence of screw loosening and, ultimately, improved patient satisfaction.

Publisher

MDPI AG

Subject

Molecular Medicine,Biomedical Engineering,Biochemistry,Biomaterials,Bioengineering,Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3