Biomimetic Material for Quantification of Methotrexate Using Sensor Based on Molecularly Imprinted Polypyrrole Film and MWCNT/GCE

Author:

Jara-Cornejo Eduardo1ORCID,Khan Sabir123ORCID,Vega-Chacón Jaime1ORCID,Wong Ademar24,da Silva Neres Lariel Chagas2,Picasso Gino1ORCID,Sotomayor Maria D. P. T.23ORCID

Affiliation:

1. Laboratory of Physical Chemistry Research, Faculty of Sciences, National University of Engineering, Av. Tupac Amaru 210, Lima 15333, Peru

2. Institute of Chemistry, São Paulo State University (UNESP), Araraquara 14801-970, Brazil

3. Department of Natural Sciences, Mathematics, and Statistics, Federal Rural University of the Semi−Arid, Mossoró 59625-900, Brazil

4. National Institute of Alternative Technologies for Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactive Agents (INCT−DATREM), Araraquara 14801-970, Brazil

Abstract

This study investigates biomimetic sensors for the detection of methotrexate contaminants in environmental samples. Sensors inspired by biological systems are the focus of this biomimetic strategy. Methotrexate is an antimetabolite that is widely used for the treatment of cancer and autoimmune diseases. Due to the widespread use of methotrexate and its rampant disposal into the environment, the residues of this drug are regarded as an emerging contaminant of huge concern, considering that exposure to the contaminant has been found to lead to the inhibition of some essential metabolic processes, posing serious risks to humans and other living beings. In this context, this work aims to quantify methotrexate through the application of a highly efficient biomimetic electrochemical sensor constructed using polypyrrole−based molecularly imprinted polymer (MIP) electrodeposited by cyclic voltammetry on a glassy carbon electrode (GCE) modified with multi−walled carbon nanotubes (MWCNT). The electrodeposited polymeric films were characterized by infrared spectrometry (FTIR), scanning electron microscopy (SEM), and cyclic voltammetry (CV). The analyses conducted using differential pulse voltammetry (DPV) yielded a detection limit of 2.7 × 10−9 mol L−1 for methotrexate, a linear range of 0.01–125 μmol L−1, and a sensitivity of 0.152 μA L mol−1. The results obtained from the analysis of the selectivity of the proposed sensor through the incorporation of interferents in the standard solution pointed to an electrochemical signal decay of only 15.4%. The findings of this study show that the proposed sensor is highly promising and suitable for use in the quantification of methotrexate in environmental samples.

Funder

PROCIENCIA,

OGI-VRI

Publisher

MDPI AG

Subject

Molecular Medicine,Biomedical Engineering,Biochemistry,Biomaterials,Bioengineering,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3