Characteristics Analysis of Volatile Organic Compounds Pollution in Residential Buildings in Northeast China Based on Field Measurement

Author:

Sun Wen1,Yan Weidong2,Huang Kailiang1,Song Jiasen3ORCID,Liu Guoqi4

Affiliation:

1. School of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, China

2. School of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China

3. School of Civil Engineering, Chongqing University, Chongqing 400044, China

4. School of Computer Science and Engineering, Shenyang Jianzhu University, Shenyang 110168, China

Abstract

A total of 8 mechanically ventilated residential buildings and 8 naturally ventilated residential buildings were selected to analyze the pollution characteristics of indoor VOCs under different ventilation modes in the severe cold area of northeast China. On typical meteorological days in each season, VOCs were detected on site, and ventilation modes were investigated by long-term online monitoring. The test results showed that the TVOC (total volatile organic compounds) concentrations varied greatly in different seasons or different functional rooms, and the TVOC concentration was the highest in winter, with a value of 0.994 mg/m3. The kitchen was the place with the most serious VOC pollution, and the TVOC concentration could reach 1.403 mg/m3. Benzene series and methylsiloxane had the highest detection rates, but the detected concentrations were low, and the average concentrations were 0.025 mg/m3 and 0.013 mg/m3 respectively. Among the VOC types with a detection rate greater than 50%, the average proportions of aldehydes, alkanes, and benzene series were 18.7%, 15.39%, and 14.38%, respectively. And their mass ratios were also high, which were 14.90%, 30.85%, and 15.70%, respectively. The annual daily average ventilation duration of mechanically ventilated residential buildings was 7.84 h longer than that of naturally ventilated residential buildings. The median TVOC concentrations of mechanically ventilated residential buildings and naturally ventilated residential buildings were 0.621 mg/m3 and 0.707 mg/m3, respectively. The fresh air system was applicable in the severe cold area of northeast China.

Funder

National Natural Science Foundation of China

Foundation of Liaoning Province Education Administration

Publisher

MDPI AG

Subject

Atmospheric Science,Environmental Science (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3