Water Losses in the Condenser Cooling System at the 905 MWe Power Unit

Author:

Pospolita Janusz,Kuczuk AnnaORCID,Widera KatarzynaORCID,Buryn ZbigniewORCID,Cholewa Robert,Drajczyk Andrzej,Pietrucha Mirosław,Smejda Rafał

Abstract

The paper focuses on water losses in the turbine condenser cooling system of the 905 MW power unit in Opole Power Plant (Opole Poland). The evaporative and drift losses are determined for various operating and atmospheric conditions. The drift loss is found to be 0.125–0.375% of the cooling water flux and some increase in this loss is noticed with increase in unit power and ambient temperature. The studies have shown that the presence of wind increases the total water loss related to the power generated by the power unit. This effect is analysed for selected constant air temperature values Tamb. The increase of the cooling water loss stream, related to the power of the unit, is at the level of 14.8% for Tamb equal to 7 °C, 23% for 15 °C, and approximately 10% at 22 °C. These increases are related to the level of losses in almost no wind conditions. It is investigated how the change in the cooling water flux affects the power unit operation and the amount of water loss. For the power unit under consideration, the reduction of the cooling water flux from 80,000 to 60,000 ton/h raises the temperature of water behind the condenser and lowers the temperature of the cooled water tw2 within the range of 0.75–1.5 °C, depending on the unit power and the ambient temperature. Reducing the cooling water flux in the analysed range results in an increase in condenser vapour pressure, within 0.5 kPa at Tamb = 25 °C. This increase is lower at lower ambient temperatures. Within the range of variations analysed, the effect of cooling water flux on evaporative losses is negligibly small. The increase in condenser steam pressure significantly affects the power generated by the turbine generator unit. The calculations show that it is possible to optimize the size of the cooling water flux for the analysed power unit and condenser cooling system. This optimization would allow (within a limited range of load variability) an increase in the net power generated by the power unit.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司