Effect of Atomic-Layer-Deposited Hydroxyapatite Coating on Surface Thrombogenicity of Titanium

Author:

Abushahba Faleh123ORCID,Areid Nagat1ORCID,Kylmäoja Elina4ORCID,Holopainen Jani5ORCID,Ritala Mikko5ORCID,Hupa Leena6,Tuukkanen Juha4,Närhi Timo17

Affiliation:

1. Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, 20520 Turku, Finland

2. Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland

3. Department of Restorative Dentistry and Periodontology, Faculty of Dentistry, Libyan International Medical University (LIMU), Benghazi 339P+62Q, Libya

4. Department of Anatomy and Cell Biology, Institute of Cancer Research and Translational Medicine, Medical Research Center, University of Oulu, 90014 Oulu, Finland

5. Department of Chemistry, University of Helsinki, 00014 Helsinki, Finland

6. Johan Gadolin Process Chemistry Center, Åbo Akademi University, 20500 Turku, Finland

7. The Wellbeing Service County Southwest Finland, 20521 Turku, Finland

Abstract

This study aimed to evaluate the surface characteristics of a nanocrystalline hydroxyapatite coating made through atomic layer deposition (ALD-HA) on titanium surfaces and to investigate its effect on blood coagulation and platelet adhesion. Grade 2 square titanium discs (0.7 cm, 1 mm thick) were used (n = 108). Half of the substrates (n = 54) were coated with ALD-HA, and the other half were used as the non-coated control. Surface free energy (SFE), contact angle (CA), surface roughness (Ra), and chemical composition were evaluated. Blood thrombogenic properties were assessed on ALD-HA and non-coated surfaces using the kinetic clotting time method. The platelets’ adhesion and morphology were also evaluated. The ALD-HA-coated surfaces demonstrated significantly higher polar SFE (p < 0.001) and lower CA (p < 0.001) values compared to the non-coated surfaces. In addition, the surface roughness was significantly lower for the ALD-HA (p < 0.001) than for the non-coated surfaces. Platelets adhered to both surfaces; however, there was variability in platelet morphologies in different areas with higher platelet density on the ALD-HA surfaces. There was no significant difference in the overall absorbance values of the hemolyzed hemoglobin for both substrates, and the total clotting time was achieved at 60 min. It can be concluded that the ALD-HA coating of titanium can enhance surface wettability, increase surface free energy, and support blood coagulation and platelet adhesion.

Publisher

MDPI AG

Subject

Materials Chemistry,Surfaces, Coatings and Films,Surfaces and Interfaces

Reference40 articles.

1. Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant Anchorage in man;Albrektsson;Acta Orthop. Scand.,1981

2. Integrity of implant surface modifications after insertion;Mints;Int. J. Oral Maxillofac. Implants,2014

3. Enhanced bone apposition to a chemically modified SLA titanium surface;Buser;J. Dent. Res.,2004

4. A comparison of hydroxyapatite (HA)-coated threaded, HA-coated cylindric, and titanium threaded endosseous dental implants;Jeffcoat;Int. J. Oral Maxillofac. Implants,2003

5. The ultrastructure of the plasma-sprayed hydroxyapatite-bone interface predisposing to bone bonding;Porter;Biomaterials,2022