Evaluation of the Corrosion Resistance of Watch Links from 316L and 904L Austenitic Stainless Steels Obtained by the Metal Injection Molding (MIM) Technique Intended to Be in Contact with Human Skin

Author:

Reclaru Lucien1ORCID,Ionescu Florina2ORCID,Diologent Frederic3

Affiliation:

1. Scientific Independent Consultant Biomaterials and Medical Devices, 103 Paul-Vouga, 2074 Marin-Epargnier, Switzerland

2. Paturle Aciers, 34, Av. Commdt L’Herminier, 38380 Saint-Laurent-du-Pont, France

3. Campus Genevois de Hautes Horlogerie, Rue de la Maladière 71C, 2000 Neuchâtel, Switzerland

Abstract

Watchmaking manufacturers obtain their bracelet links from machining drawn metal profiles. But, today, there is another process that represents an alternative to manufacture them: metal injection molding using metal powders (MIM technology). This process is less expensive than the machining of drawn metal profiles. The aim of this study was to evaluate the corrosion behavior and the nickel cation release of two stainless steel alloys: 316L MIM and 904L MIM. The general corrosion behavior was evaluated by the rotating electrode technique; the galvanic corrosion measurements were conducted with a 316L AISI bulk coupling partner. The pitting corrosion behavior was evaluated in FeCl3 0.5 M media (according to ASTM G48-11). For comparison, a complementary study was conducted on 316L and 904L bulk alloys. The Ni cation release tests were conducted on 316L and 904L MIM and bulk samples according to EN 1811. Different electrochemical parameters were measured and calculated (open circuit potential, polarization resistance, corrosion current and Tafel slopes, coulometric analysis). Generally, if MIM steels are compared with conventional steels, their corrosion resistance behavior is inferior. In the couplings studied, the galvanic currents generated are very important. The shape of the curves also reveals the presence of localized corrosion phenomena. According to tests in ferric chloride, MIM steels were noted to have inferior behavior compared to conventional steels. MIM type 904L steels are comparable in behavior to conventional type 316L steels. The quantities of nickel released according to EN 1811 were very significant (2 mg cm−2 week−1 up to 24 mg cm−2 week−1) and did not meet the requirements of the European directive (0.5 µg cm−2 week−1). In conclusion, conventional steels studied under the same experimental conditions revealed a better behavior compared to MIM steels independently of the phenomenological parameters chosen.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3