PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility

Author:

Jia Ziyang,Ma Chunyang,Zhang Hongbin

Abstract

PLGA (Poly lactic-co-glycolic acid) and PLGA drug-loading coatings were prepared on 316 L stainless steel by electrostatic spray deposition (ESD). The surface morphology, three-dimensional morphology, and crystal structures of the coatings were observed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray diffraction (XRD). Thermal properties, molecular weight, and coating composition were studied by differential scanning calorimetry (DSC), gel permeation chromatography (GPC), and NMR. The degradation behaviors of the coatings were studied by mass changes, relative molecular mass and distributions, polymer compositions, thermal properties, and surface morphologies. The blood compatibilities of the coatings were investigated by platelet adhesion testing and dynamic coagulation times. SEM results indicated the drug-loading coating with 33% RAPA had the smoothest and most compact morphology. Addition of RAPA decreased the Tg of the PLGA coating, accompanied by partial crystallization that slowed the degradation rate of the drug-loaded coating. Microscopically, the morphology of the PLGA drug-loaded coating was coarser than the PLGA coating. The average surface roughness values of line and surface scannings were 16.232 nm and 39.538 nm, respectively. The surface of the drug-loading coating was micro uneven, and the macro smooth and micro multiphase separation structure helped improve its blood compatibility.

Publisher

MDPI AG

Subject

Materials Chemistry,Surfaces, Coatings and Films,Surfaces and Interfaces

Reference32 articles.

1. Lipoprotein-associated Phospholipase A2 and Coronary Heart Disease

2. Effect of severe stenosis or occlusion of small vessel on coronary artery after cardiac stent implantation on cardiac function;Zheng;Clin. Res. Pract.,2018

3. Zinc-based alloys for degradable vascular stent applications

4. TCTAP A-085 Vascular Response to Drug-eluting Stent with Biodegradable Versus Durable Polymer

5. Coronary stents and vascular response to implantation: Literature review;Francesca;Pragmat. Obs. Res.,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3