Abstract
This study intends to explore the influence of a fabric electrode skin interface filling medium on ECG signals under dynamic and static conditions, so as to be able to better monitor both stable and dynamic ECG signals. In this paper, cotton fabric electrodes were prepared using electroless silver-plated conductive cotton fabric, and then the electrodes were integrated into a physiotherapy-grade elastic bandage to assemble the fabric ECG tape. The electrode impedance tester and the BIOPAC physiological recorder were used to measure the fabric electrode-skin impedance and electrocardiogram under dynamic and static conditions, respectively. Later, the influence of the fabric electrode coated medium on the acquisition effect of an electrocardiogram signal under dynamic and static conditions is discussed. The results show that in the absence of a dielectric reagent coating, the cotton fabric electrode is easily disturbed by external noise which leads to large electrode-skin contact impedance. However, the electrode-skin contact impedance is greatly reduced after coating the fabric electrode with the dielectric reagent. At the same time, after applying the conducive paste coating, the corresponding change curve of the fabric electrode became more stable, and the impedance value was less than 0.005 MΩ·cm2, which meets the standard requirement for textile dry electrode skin impedance. In a state of rest, a clear and stable ECG can be collected regardless of whether the medium reagent is coated or not. However, only after applying the conductive paste can a stable ECG signal be collected under the three motion modes, or can a P wave, QRS wave group, or T wave be clearly distinguished. In addition, there is a high correlation with the disposable gel electrode, which can satisfy the requirements of the long-term monitoring of ECG signals under dynamic conditions.
Funder
National Natural Science Foundation of China
Education Department of Henan Province
Zhongyuan University of Technology
the Science and Technology Guidance Project of China National Textile and Apparel Council
Subject
Materials Chemistry,Surfaces, Coatings and Films,Surfaces and Interfaces
Reference25 articles.
1. Next Steps in Primary Prevention of Coronary Heart Disease Rationale for and Design of the ECAD Trial;Domanski;J. Am. Coll. Cardiol.,2015
2. Research status and development trend of wearable medical monitoring clothing;Yan;J. Text.,2015
3. (2020). China Cardiovascular Health and Disease Report. J. Cardiopulm. Vasc. Dis., 39, 1157–1162.
4. Lou, C., Li, R., Li, Z., Liang, T., Wei, Z., Run, M., Yan, X., and Liu, X. (2016). Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring. Sensors, 16.
5. Fernandes, M.S., Lee, K.S., Ram, R.J., Correia, J.H., and Mendes, P.M. (September, January 31). Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices. Proceedings of the 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, Buenos Aires, Argentina.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献