Abstract
This study uses a simplified two-dimensional time-dependent computational fluid dynamic (CFD) model to study the influence of wall shelf configuration and outtake honeycomb inclination angle on the performance of the air curtain in an open-type semi-vertical refrigerated display cabinet. Numerical simulation results show that changing the angle, along with changing the shelf configuration, can reduce the temperature of the intake air grille and improve the warm/cold air ratio. The average temperature of the simulated food products decreased by 1.2 °C compared to the unmodified display cabinet and began to meet the requirements of the temperature category 3M0. The proposed CFD model was validated by the experimental results. The simulation results obtained are important for cabinet design to improve product storage quality and reduce energy consumption.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference15 articles.
1. CFD comparisons of open-type refrigerated display cabinets with/without air guiding strips
2. Energy Use of Doored and Open Vertical Refrigerated Display Cases;Fricke;Proceedings of 13th International Refrigeration and Air Conditioning Conference, Purdue University,2010
3. Efficient display case refrigeration;Faramarzi;ASHRAE J.,1999
4. Experimental analysis of heat transfer and airflow in a closed refrigerated display cabinet
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献