Assessment of Hyperglycemia, Hypoglycemia and Inter-Day Glucose Variability Using Continuous Glucose Monitoring among Diabetic Patients on Chronic Hemodialysis

Author:

Divani Maria,Georgianos Panagiotis I.,Didangelos TriantafyllosORCID,Liakopoulos VassiliosORCID,Makedou KaliORCID,Iliadis Fotios,Savopoulos Christos,Grekas Dimitrios M.

Abstract

Continuous glucose monitoring (CGM) facilitates the assessment of short-term glucose variability and identification of acute excursions of hyper- and hypo-glycemia. Among 37 diabetic hemodialysis patients who underwent 7-day CGM with the iPRO2 device (Medtronic Diabetes, Northridge, CA, USA), we explored the accuracy of glycated albumin (GA) and hemoglobin A1c (HbA1c) in assessing glycemic control, using CGM-derived metrics as the reference standard. In receiver operating characteristic (ROC) analysis, the area under the curve (AUC) in diagnosing a time in the target glucose range of 70–180 mg/dL (TIR70–180) in <50% of readings was higher for GA (AUC: 0.878; 95% confidence interval (CI): 0.728–0.962) as compared to HbA1c (AUC: 0.682; 95% CI: 0.508–0.825) (p < 0.01). The accuracy of GA (AUC: 0.939; 95% CI: 0.808–0.991) in detecting a time above the target glucose range > 250 mg/dL (TAR>250) in >10% of readings did not differ from that of HbA1c (AUC: 0.854; 95% CI: 0.699–0.948) (p = 0.16). GA (AUC: 0.712; 95% CI: 0.539–0.848) and HbA1c (AUC: 0.740; 95% CI: 0.570–0.870) had a similarly lower efficiency in detecting a time below target glucose range < 70 mg/dL (TBR<70) in >1% of readings (p = 0.71). Although the mean glucose levels were similar, the coefficient of variation of glucose recordings (39.2 ± 17.3% vs. 32.0 ± 7.8%, p < 0.001) and TBR<70 (median (range): 5.6% (0, 25.8) vs. 2.8% (0, 17.9)) were higher during the dialysis-on than during the dialysis-off day. In conclusion, the present study shows that among diabetic hemodialysis patients, GA had higher accuracy than HbA1c in detecting a 7-day CGM-derived TIR70–180 < 50%. However, both biomarkers provided an imprecise reflection of acute excursions of hypoglycemia and inter-day glucose variability.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3