Affiliation:
1. Precision Engineering Laboratory, Department of Mechanical Engineering and Mechatronics, OWL University of Applied Sciences and Arts, 32657 Lemgo, Germany
Abstract
For modern machines, factories and electric and autonomous vehicles, the importance of vreliable electrical connectors cannot be overstated. With an increasing number of connectors being used in machines, factories and vehicles, ensuring their reliability is crucial for comfort and safety alike. One of the key indicators of reliability is the lifetime of connectors. To evaluate the lifetime of electrical connectors, a testing method and a model for calculating their lifetime based on the test data were developed. The results from these tests were compared to failure analysis data from long-term field operations. The findings indicate that the laboratory tests can accurately reproduce the main failures observed in the field. However, such lifetime tests can be time- and labor-intensive. To address this challenge, a data-driven method is proposed that predicts the lifetime of electrical connectors using statistical analysis of electrical contact resistance data collected from short-term tests. The predictions from this method were compared to actual results obtained from long-term tests. A strong correlation was observed between the contact resistance development in short-term tests and the number of failures in later stages of testing. Thus, apart from predicting the lifetime of connectors, this method can also be applied for failure prognosis in real-time operations.
Funder
the German Federal Ministry for Economic Affairs and Climate Action
Reference37 articles.
1. International Organization for Standardization (2016). Road Vehicles—Functional Safety—Part 5: Product Development at the Hardware Level, Genf, International Organization for Standardization.
2. Hilmert, D., Yuan, H., and Song, J. (2022, January 23–26). The Analysis of Failure Mechanisms of Electrical Connectors in Long-term Use Field Vehicles. Proceedings of the 2022 IEEE 67th Holm Conference on Electrical Contacts, Tampa, FL, USA.
3. Environmental degradation of utility power connectors in a harsh environment;Callen;IEEE Trans. Compon. Packag. Technol.,2000
4. Song, J., Yuan, H., and Koch, C. (2018, January 14–18). Accelerated Testing of Electromechanical Connectors Considering Thermal and Mechanical Loads. Proceedings of the 2018 IEEE 64th Holm Conference on Electrical Contacts, Albuquerque, NM, USA.
5. Kyeong, S., and Pecht, M.G. (2020). Electrical Connectors: Design, Manufacture, Test, and Selection, John Wiley & Sons.