The Inertial Disturbances of Fluid Movement in the Chamber of a Liquid Autobalancer

Author:

Lozynskyi Vasyl1ORCID,Shihab Thaer23,Drach Ilona4,Ropyak Liubomyr5

Affiliation:

1. Belt and Road Initiative Center for Chinese-European Studies (BRICCES), Guangdong University of Petrochemical Technology, Maoming 525000, China

2. Medical Instruments Techniques Engineering Department, Technical College of Engineering, Al-Bayan University, International Airport Road, Near of Abbas Bin Firnas Sq., Baghdad 10070, Iraq

3. Department of Welding, Ivano-Frankivsk National Technical University of Oil and Gas, 76019 Ivano-Frankivsk, Ukraine

4. Department of Tribology, Automobiles and Materials Science, Faculty of Engineering, Transport and Architecture, Khmelnytskyi National University, 11 Institutska Str., 29016 Khmelnitskiy, Ukraine

5. Department of Computerized Mechanical Engineering, Ivano-Frankivsk National Technical University of Oil and Gas, 15 Karpatska Str., 76019 Ivano-Frankivsk, Ukraine

Abstract

This article analyses the problem of automatic balancing rotors with a liquid balancer, which is a cylindrical chamber partially filled liquid of a certain density. This problem is related to the problem of the dynamics of bodies with cavities partially filled with liquid. As part of this task, we analyzed disturbances in the relative motion of the fluid in the ABD chamber caused by the Coriolis force inertia. The distortions of the free surface of the liquid were found, resonant phenomena in the flow of the working fluid were investigated, and the physical explanation of the received results given should be taken into account when designing the corresponding ones self-balancing devices. It was established that the axial component of the Coriolis inertial force causes peculiar wave phenomena in the correcting fluid movement. For the given nature of undisturbed motion, the conditions of this phenomenon’s occurrence are determined only by the geometric dimensions of the cylindrical chamber and the thickness of the liquid layer in undisturbed motion, and do not depend on the intensity of rotation of the liquid, nor on its density. It is shown that a decrease in the “ABD chamber height–radius” ratio leads to stabilization of the movement of the system. Experimental verification has been performed; theoretical results on the developed stand for work research rotor system with a vertical axis of rotation.

Funder

Guangdong University of Petrochemical Technology

Ministry of Education and Science of Ukraine

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3