Abstract
This paper studies the electromechanical characteristics of synchronous generators under dynamic stator interturn short circuit (DSISC). First, the air gap magnetic flux density (MFD) of the generator under normal and DSISC fault was obtained. Then, the expression for the phase current and the electromagnetic torque (EMT) were obtained. After this, the phase current and EMT were analyzed by finite element analysis (FEA). Finally, the measured electromechanical characteristics of the CS-5 generator under different conditions were analyzed in accordance with theory and simulation. It was shown that with the occurrence, and deterioration, of DSISC, the amplitude of the first harmonic, third harmonic and fifth harmonic of the phase current became more affected by the pulse. Meanwhile, the even-numbered harmonics components of EMT increased.
Funder
National Natural Science Foundation of China
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering,Control and Optimization,Mechanical Engineering,Computer Science (miscellaneous),Control and Systems Engineering
Cited by
1 articles.
订阅此论文施引文献