Abstract
Highly enhanced pump power density inevitably results in a profound rise in pump temperature, which seriously influences both power loss and service performance. Heat loss analysis is an important part of analyzing the mechanical and cooling efficiency of a 2D piston pump. This paper focuses on heat loss analysis of this pump’s transmission. Firstly, theoretical and experimental studies are carried out on the thermal–hydraulic model to investigate the heat loss of the pump’s transmission. A pump test rig is developed and thermal experiments are conducted, from 1000 rpm to 6000 rpm. Furthermore, its transient thermal simulation model is implemented with Ansys software to capture the pump’s thermal status. The test convective heat transfer coefficients and temperature data are set in the model, and the simulation results are mutually validated with the experimental ones. Finally, the transmission’s heat loss is compared with its reference churning loss formula. The distribution of the transient heat loss is 49.66% into the end cap, 27.74% into the cylinder head, 13.30% into the inner cylinder, and 9.30% into the oil. The heat loss simulation results agree with the churning loss below 4000 rpm; therefore, the transmission thermal model is accurate and efficient.
Funder
National Key Research and Development Program of China
Natural Science Foundation of Zhejiang Province
Department of Education of Zhejiang Province
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering,Control and Optimization,Mechanical Engineering,Computer Science (miscellaneous),Control and Systems Engineering
Cited by
1 articles.
订阅此论文施引文献