Evaluation of Implant Stability According to Implant Placement Site and Duration in Elderly Patients: A Prospective Multi-Center Cohort Study

Author:

Shim Ji-Suk1,Kim Moon-Young2ORCID,An Se-Jun3,Kang Eun-Sung2,Choi Yu-Sung3ORCID

Affiliation:

1. Department of Dentistry, Korea University Guro Hospital, Seoul 08308, Republic of Korea

2. Department of Oral and Maxillofacial Surgery, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea

3. Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan 31116, Republic of Korea

Abstract

The aim of this prospective study is to investigate implant stability and the reliability of different measuring devices according to implant placement site and duration in patients aged over 65 years. The study evaluated 60 implants (diameter: 3.5/4.0/4.5/5.0 mm and length: 8.5/10.0/11.5 mm) in 60 patients aged ≥ 65 years. The implant placement sites were divided into six evenly distributed sections (n = 10), i.e., maxillary right-posterior, A; maxillary anterior, B; maxillary left-posterior, C; mandibular right-posterior, D; mandibular anterior, E; mandibular left-posterior, F. Participants visited the hospital six times: implant surgery, 1V; stitch removal, 2V; 1-month follow-up, 3V; 2-month follow-up, 4V; before final restoration delivery, 5V; and after final restoration delivery, 6V. The implant stability was evaluated with the Osstell Mentor (ISQ), Periotest M (PTV), and Anycheck (IST). The mean values of ISQ, PTV, and IST were analyzed (α = 0.05). ISQ, PTV, and IST results of 4V and 5V were significantly higher than those of 1V (p < 0.05). The lowest ISQ results occurred in the E location at 4V and 5V (p < 0.05). In all mandibular locations, IST results of 6V were significantly higher than those of 1V, 2V, 3V, and 4V (p < 0.05). ISQ results were negatively correlated with PTV and positively correlated with IST, and PTV was negatively correlated with IST. By considering various factors affecting the stability of the implant, it is necessary to determine the appropriate implant load application time. This could help increase the implant success rate in elderly patients. And as a diagnostic device for implant stability and the evaluation of osseointegration in elderly patients, Anycheck was also able to prove its relative reliability compared to Osstell ISQ Mentor and Periotest M.

Funder

Korea Medical Device Development Fund

National Research Foundation of Korea

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3