Idiopathic Ventricular Arrhythmias Originating from Different Portions of the Coronary Venous System: Prevalence, Electrocardiographic Characteristics, Catheter Ablation, and Complications

Author:

Wang Yaoji,Shao Jiameng,Shen Bing,Zheng Cheng,Li Jin,Xu Que,Lin Yifan,Lin Jiafeng

Abstract

(1) Background: To determine the prevalence, electrocardiographic characteristics, mapping, and ablation of IVAs arising from the CVS. (2) Methods: Detailed activation and pace mapping of the CVS IVAs was performed before attempted radiofrequency ablation (RFCA). (3) Results: The IVAs originating from the vicinity of the CVS represented approximately 5.27% (164/3113) of all IVAs; 94.51% (155/164) cases were accessed at the earliest identified site and 83.54% (137/164) IVAs were successfully ablated. The main coronary vein group had a relatively short procedure time, short fluoroscopy time, fewer radiofrequency lesions prior to success, and less Swartz sheath support. IVAs originating from the CVS had distinct ECG characteristics: Rs, RS or rS (with s or S) wave in lead V1 indicate the Vas arising from the proximal portion of the anterior interventricular vein (AIV) and summit-CV; Rs (with s or S) wave in leads V5–V6 indicate the Vas arising from the adjacent regions of the distal great cardiac vein 1 (DGCV1); positive wave (R, Rs or r) In lead I indicate the VAs ori”inat’ng from Summit-CV and posterior wall subgroup (including middle cardiac vein [MCV], posterior lateral vein [PLV], coronary sinus [CS]). Compared with the IVAs originating from the endocardial mitral annulus, a PdW > 45 ms, an IDT > 74 ms, and an MDI > 0.50 indicate a CVS origin of the IVAs. The common peri-procedure complications were CV dissection (6.45%, 10/155), CV rupture (1.29%, 2/155), coronary artery spasm (1.29%, 2/155), coronary artery stenosis (0.65%, 1/155), pericardial effusion (0.65%, 1/155) and tamponade (1.29%, 2/155). Stenosis of coronary arteries was not observed at the adjacent ablation site in the CVS during follow-up. (4) Conclusions: vAs arising from the CVS are not a rare phenomenon. Several ECG and procedure characteristics could help regionalize, map, and ablate the origin of IVAs from different portions of the CVS. RFCA within the CVS was relatively effective and safe.

Funder

Wenzhou Municipal Sci-Tech Bureau

Zhejiang Provincial Natural Science Foundation

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3