Abstract
Photoplethysmography (PPG) is a noninvasive optical technology with applications including vital sign extraction and patient monitoring. However, its current use is primarily limited to heart rate and oxygenation monitoring. This study aims to demonstrate the utility of PPG for physiological investigations. In particular, we sought to demonstrate the utility of simultaneous data acquisition from several regions of tissue using remote/contactless PPG (rPPG). Specifically, using a high-speed scientific-grade camera, we collected rPPG from the hands (palmar/dorsal) of 22 healthy volunteers. Data collected through the red and green channels of the RGB CMOS sensor were analyzed. We found a statistically significant difference in the amplitude of the glabrous skin signal over the non-glabrous skin signal (1.41 ± 0.85 in the red channel and 2.27 ± 0.88 in the green channel). In addition, we found a statistically significant lead of the red channel over the green channel, which is consistent between glabrous (17.13 ± 10.69 ms) and non-glabrous (19.31 ± 12.66 ms) skin. We also found a statistically significant lead time (32.69 ± 55.26 ms in the red channel and 40.56 ± 26.97 ms in the green channel) of the glabrous PPG signal over the non-glabrous, which cannot be explained by bilateral variability. These results demonstrate the utility of rPPG imaging as a tool for fundamental physiological studies and can be used to inform the development of PPG-based devices.
Funder
NSERC Alliance
NSERC Personal Discovery
NSERC RTI
Toronto Metropolitan University Health Fund
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference20 articles.
1. Kyriacou, P.A., and Allen, J. (2021). Photoplethysmography: Technology, Signal Analysis and Applications, Academic Press.
2. Respiration Signals from Photoplethysmography;Nilsson;Obstet. Anesthesia Dig.,2013
3. Burton, T., Saiko, G., and Douplik, A. (2022, January 12–15). Remote PPG Imaging by a Consumer-grade Camera under Rest and Elevation-invoked Physiological Stress Reveals Mayer Waves and Venous Outflow. Proceedings of the 15th International Joint Conference on Biomedical Engineering Systems and Technologies—BIOIMAGING, Lisbon, Portugal.
4. The Emerging Role of Wearable Technologies in Detection of Arrhythmia;Cheung;Can. J. Cardiol.,2018
5. Investigating the origin of photoplethysmography using a multiwavelength Monte Carlo model;Chatterjee;Physiol. Meas.,2020