Fractional Exhaled Nitric Oxide (FeNO) in Patients with Stable Chronic Obstructive Pulmonary Disease: Short-Term Variability and Potential Clinical Implications

Author:

Ambrosino PasqualeORCID,Fuschillo Salvatore,Accardo Mariasofia,Mosella Marco,Molino AntonioORCID,Spedicato Giorgio Alfredo,Motta AndreaORCID,Maniscalco MauroORCID

Abstract

Background: The use of fractional exhaled nitric oxide (FeNO) has been proposed for identifying and monitoring eosinophilic airway inflammation in chronic obstructive pulmonary disease (COPD). To explore the clinical utility of FeNO in COPD, we aimed to assess its short-term variability in a clinically stable COPD cohort. Methods: Consecutive COPD patients, formerly smokers, underwent FeNO assessment at the baseline and six time-points through serial sampling spaced 3 days apart. Results: A total of 41 patients (mean age 72.9, 87.8% males) showed a median baseline value of FeNO of 11.7 (8.0–16.8) ppb. A weak linear relationship was documented between baseline FeNO values and both eosinophil counts (r = 0.341, p = 0.029) and the percentage of eosinophils (r = 0.331, p = 0.034), confirmed in multiple linear regressions after adjusting for steroid use. The overall individual variability of FeNO between time-points was 3.90 (2.53–7.29) ppb, with no significant difference in the distribution of FeNO values measured at different time-points (p = 0.204). A total of 28 (68.3%) patients exhibited FeNO always below the 25 ppb cut-off at all determinations, while the remining 13 (31.7%) had at least one value above the established limit. Interestingly, none of these 13 participants had FeNO stably above 25 ppb, all showing at least one normal value during serial sampling. Compared to these patients with more fluctuating values, the 28 with stably normal FeNO only exhibited a significantly higher body weight (80.0 ± 18.2 kg vs. 69.0 ± 8.8 kg, p = 0.013) and body mass index (29.7 ± 6.5 kg/m2 vs. 25.9 ± 3.7 kg/m2, p = 0.026), confirmed in multiple logistic regressions after adjusting for major potential confounders. Conclusions: A certain degree of FeNO variability, apparently unrelated to eosinophil counts but somehow influenced by body weight, must be considered in COPD patients. Further studies are needed to clarify whether this biomarker may be effectively used to plan more personalized pharmacological and rehabilitation strategies in this clinical setting.

Funder

“Ricerca Corrente” funding scheme of the Ministry of Health, Italy

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3