Vascular Access Flow during Dialysis: Does Needle Orientation Matter?

Author:

Tsangalis Georgios,Loizon Valérie

Abstract

Background: Monitoring of vascular access outflow (VAO) in dialysis is based on the indicator dilution method by ultrasound (UD). The role of arterial needle orientation in VAO measurement is not clear. We compared the impact of the retrograde (RET) versus the antegrade orientation (ANT) in terms of (a) VAO (UD) and (b) dialysis adequacy. Moreover, we compared VAO (UD ANT and RET orientation) with VAO measured by Doppler ultrasound. Methods: 22 patients participated in the study. Inclusion criteria: Dialysis > 6 months with a functioning AVF, no stenosis, no active infection, EF > 45% and informed consent. 4 flow measurements were taken on the same dialysis day (4 consecutive weeks). To account for blood pressure variation, we “corrected” VAO for a mean arterial pressure of 100 mmHg. Doppler VAO was measured just before dialysis. Means were compared by the paired t-test. For correlation and agreement, linear regression and Bland-Altman analysis were performed respectively. Results: Mean VAO (UD) was higher in the (ANT) versus the (RET) orientation: 1286.17 mL/min (SD = 455.78, 95%CI = 1084–1488) versus 1189.96 mL/min (SD = 401.05, 95%CI = 1012–1368) (p = 0.013) with a mean difference of 96.21 mL/min (5.66%). Mean Kt/V (RET orientation) was 1.57 (SD = 0.10, 95%CI = 1.52–1.61) versus 1,55 (SD = 0.10, 95%CI = 1.50–1.60) (ANT) orientation (p = 0.062). Recirculation was always 0%. The mean VAO (Doppler) was 1079.54 mL/min (SD = 356.04, 95%CI = 922–1237), 16% lower than VAO measured by UD with (ANT) orientation (p = 0.009) and 9.3% lower than the VAO in the (RET) orientation (p = 0.113). Linear regression analysis showed that VA flows (ANT versus RET) orientation of the needle correlates well between them (r = 0.93, p < 0.001) but show poor agreement (Bland–Altman analysis). Conclusion: VAO (UD) in the RET orientation was significantly lower than VAO in the ANT orientation and more consistent with VAO assessed by Doppler without influencing dialysis adequacy. Therefore, when using UD for VAO surveillance, the RET orientation should be used.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3