Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations

Author:

Thangwarawut Pisut,Amornvit PokpongORCID,Rokaya DineshORCID,Kiattavorncharoen Sirichai

Abstract

This research aimed to compare the accuracy of dental implant placement among three types of surgical guide: metal sleeve with key handle (Nobel guide, Nobel Biocare, Göteborg, Sweden), metal sleeve without key handle, and non-sleeve without key handle (Dentium full guide kit, Dentium Co., Seoul, Korea) when placing the implant in different bone inclinations. A total of 72 polyurethane bone models were fabricated in different inclinations (0°, 45°, and 60°). The dental implants were placed in bone models following the company’s recommendations. After dental implants were installed, the digital scans were done by an extraoral scanner. The deviations of the dental implant position were evaluated by superimposition between post-implant placement and reference model by using GOM inspect software. The deviation measurement was shown in 5 parameters: angular deviation, 3D deviation at the crest, 3D deviation at the apex, lateral linear deviation, and vertical linear deviation. The data were analyzed using One-way ANOVA and post-hoc tests at a significance level of 0.05. The accuracy of the dental implant position was not significantly influenced by the difference in the surgical guide system (p > 0.05). There were significant differences between placed and planned implant positions in the different inclinations of the bone. A significant difference was found in all parameters of 0° and 60° bone inclinations (p < 0.05). At 0° and 45°, angulated bone showed significant differences except in 3D deviation at the apex. Between 45° and 60° were significant differences only in angular deviation. Within the limitations of this study, the accuracy of implant placement among three types of surgical guides (Non-sleeve without key handle, Metal sleeve without key handle, and Metal sleeve with key handle) from two companies (Dentium and Nobel Biocare) was similar. Hence, the operators can choose the surgical guide system according to their preference. The inclination of bone can influence the angulation of dental implants.

Publisher

MDPI AG

Subject

General Materials Science

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3