Author:
Simpson Chris A.,Knowles David M.,Mostafavi Mahmoud
Abstract
Accurate residual lattice strain measurements are highly dependent upon the precision of the diffraction peak location and the underlying microstructure suitability. The suitability of the microstructure is related to the requirement for valid powder diffraction sampling statistics and the associated number of appropriately orientated illuminated. In this work, these two sources of uncertainty are separated, and a method given for both the quantification of errors associated with insufficient grain sampling statistics and minimization of the total lattice strain measurement uncertainty. It is possible to reduce the total lattice strain measurement uncertainty by leveraging diffraction peak measurements made at multiple azimuthal angles. Lattice strain measurement data acquired during eight synchrotron X-ray diffraction experiments, monochromatic and energy dispersive, has been assessed as per this approach, with microstructural suitability being seen to dominate total measurement uncertainty when the number of illuminated grains was <106. More than half of the studied experimental data fell into this category, with a severe underestimation of total strain measurement uncertainty being possible when microstructural suitability is not considered. To achieve a strain measurement uncertainty under 10−4, approximately 3×105 grains must be within the sampled gauge volume, with this value varying with the multiplicity of the family of lattice planes under study. Where additional azimuthally arrayed data are available an in-plane lattice strain tensor can be extracted. This improves overall strain measurement accuracy and an uncertainty under 10−4 can then be achieved with just 4×104 grains.
Funder
Engineering and Physical Sciences Research Council
Subject
General Materials Science,Metals and Alloys
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献