Abstract
The article presents research on the influence of the type of UHF antenna and the type of machine learning algorithm on the effectiveness of classification of partial discharges (PD) occurring in the insulation system of a power transformer. For this purpose, four antennas specially adapted to be installed in the transformer tank (UHF disk sensor, UHF drain valve sensor, planar inverted F-type antenna, Hilbert curve fractal antenna) and a reference log-periodic antenna were used in laboratory tests. During the research, the main types of PD, typical for oil-paper insulation, were generated, i.e., PD in oil, PD in oil wedge, PD in gas bubbles, surface discharges, and creeping sparks. For the registered UHF PD pulses, nine features in the frequency domain and four features in the wavelet domain were extracted. Then, the PD classification process was carried out with the use of selected methods of supervised machine learning. The study investigated the influence of the number and type of feature on the obtained classification results gained with the following machine-learning methods: decision tree, support vector machine, Bayes method, k-nearest neighbor, linear discriminant, and ensemble machine. As a result of the works carried out, it was found that the highest accuracies are gathered for the feature representing peak frequency using a decision tree, reaching values, depending on the type of antenna, from 89.7% to 100%, with an average of 96.8%. In addition, it was found that the MRMR method reduces the number of features from 13 to 1 while maintaining very high effectiveness. The broadband log-periodic antenna ensured the highest average efficiency (100%) in the PD classification. In the case of the tested antennas adapted to work in an energy transformer tank, the highest defect-recognition efficiency is provided by the UHF disk sensor (99.3%), and the lowest (89.7%) is by the UHF drain valve sensor.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Reference82 articles.
1. An overview of state-of-the-art partial discharge analysis techniques for condition monitoring
2. Transformer Reliability Survey;Tenbohlen,2015
3. IEC TS 62478:2016, High Voltage Test Techniques—Measurement of Partial Discharges by Electromagnetic and Acoustic Methods,2016
4. Location and Interpretation of Sources of Acoustic Emissions from Electrical Discharges in Power Transformers and Power Reactors,2019
5. A review of dissolved gas analysis measurement and interpretation techniques