A Novel Tactile Function Assessment Using a Miniature Tactile Stimulator

Author:

Sung Chung-Tung12,Wang Yung-Jung12,Huang Jian-Jia345ORCID,Pei Yu-Cheng2345,Lin Lei-Chi2,Mai Wen-Hsin6,Chang Bao-Luen27ORCID

Affiliation:

1. Department of Medical Education, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan

2. School of Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan

3. Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan

4. Center of Vascularized Tissue Allograft, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan

5. Master of Science Degree Program in Innovation for Smart Medicine, Chang Gung University, Taoyuan 33302, Taiwan

6. School of Chinese Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan

7. Department of Neurology, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan

Abstract

Several methods for the measurement of tactile acuity have been devised previously, but unexpected nonspatial cues and intensive manual skill requirements compromise measurement accuracy. Therefore, we must urgently develop an automated, accurate, and noninvasive method for assessing tactile acuity. The present study develops a novel method applying a robotic tactile stimulator to automatically measure tactile acuity that comprises eye-opened, eye-closed training, and testing sessions. Healthy participants judge the orientation of a rotating grating ball presented on their index fingerpads in a two-alternative forced-choice task. A variable rotation speed of 5, 10, 40, or 160 mm/s was used for the tactile measurement at a variety of difficulties. All participants met the passing criteria for the training experiment. Performance in orientation identification, quantified by the proportion of trials with correct answers, differed across scanning directions, with the highest rotation speed (160 mm/s) having the worst performance. Accuracy did not differ between vertical and horizontal orientations. Our results demonstrated the utility of the pre-test training protocol and the functionality of the developed procedure for tactile acuity assessment. The novel protocol performed well when applied to the participants. Future studies will be conducted to apply this method to patients with impairment of light touch.

Funder

Chang Gung Medical Foundation

Taiwan’s Ministry of Science and Technology

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3