Co-Dependency of IAQ in Functionally Different Zones of Open-Kitchen Restaurants Based on Sensor Measurements Explored via Mutual Information Analysis

Author:

Maciejewska Monika1ORCID,Azizah Andi1,Szczurek Andrzej1ORCID

Affiliation:

1. Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wroclaw, Poland

Abstract

High-quality indoor air is essential in open-kitchen restaurants for ensuring a healthy workplace and comfortable conditions for visitors. In this study, indoor air quality interdependence between the kitchen and the dining zones in open-kitchen restaurants was analyzed. The method was based on measurements of selected air parameters using a sensor technique and mutual information (MI) analysis. A long-term approach (based on a several-hour time series) and a short-term approach (based on a several-minute time series) were applied. This study involved four open-kitchen restaurants. The indoor conditions were represented by the temperature, relative humidity, CO2 concentration, and content of the total volatile organic compounds (TVOC) in the air. The MI analyses showed that the long-term co-dependence of the indoor conditions between the kitchen and the dining zones was smaller during business hours (MI = 0.12 ÷ 0.40) compared to night hours (MI = 0.24 ÷ 0.58). The ranking of the long-term MI values for the individual air parameters was MICO2 (0.34) ≅ MIT (0.34) > MIRH (0.28) > MITVOC (0.23). The short-term interdependencies were smaller during night hours (median MI = 0.01 ÷ 0.56) compared to business hours (MI = 0.23 ÷ 0.61). Additionally, the short-term MI was subject to high temporal variability. The ranking of the short-term MI values for the individual air parameters was MICO2 (0.48) > MIT (0.46) > MIRH (0.37) > MITVOC (0.26). Due to the weak and highly variable co-dependence of the air parameters between the kitchen and dining areas, multi-zone monitoring of air parameters with an emphasis on TVOC measurements is recommended to ensure proper indoor conditions in open-kitchen restaurants. The presented approach may be applied to design indoor air quality monitoring and ventilation systems not only in open-kitchen restaurants but also in other interiors with functionally different zones.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference38 articles.

1. Aspects of openness in Hong Kong coffee shops;Barber;Interiors,2022

2. Can signaling impact customer satisfaction and behavioral intentions in times of service failure? Evidence from open versus closed kitchen restaurants;Byun;J. Hosp. Mark. Manag.,2019

3. Basu, A. (2023, August 20). Pros and Cons of Open Kitchens in the Restaurant Industry. Available online: https://modernrestaurantmanagement.com/pros-and-cons-of-open-kitchens-in-restaurant-industry/.

4. Nisbets Australia (2023, August 20). Why do Restaurants Have Open Kitchens?. Available online: https://www.nisbets.com.au/why-do-restaurants-have-open-kitchens.

5. Open kitchen vs. closed kitchen: Does kitchen design affect customers causal attributions of the blame for service failures?;Byun;Int. J. Contemp. Hosp. Manag.,2018

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3