Knee Arthrodesis with a Modular Silver-Coated Endoprosthesis for Infected Total Knee Arthroplasty with Extensive Bone Loss: A Retrospective Case-Series Study

Author:

Savvidou Olga D.1ORCID,Kaspiris Angelos2ORCID,Goumenos Stavros1,Trikoupis Ioannis1,Melissaridou Dimitra1ORCID,Kalogeropoulos Athanasios3ORCID,Serenidis Dimitris1,Georgoulis Jim-Dimitris1,Lianou Ioanna4ORCID,Koulouvaris Panagiotis1ORCID,Papagelopoulos Panayiotis J.1

Affiliation:

1. Medical School, First Department of Orthopedics, Attikon University Hospital, National and Kapodistrian University of Athens, 12462 Athens, Greece

2. Laboratory of Molecular Pharmacology, School of Health Sciences, University of Patras, 26504 Patras, Greece

3. Sonnenhospital, 3006 Bern, Switzerland

4. Department of Orthopaedics, Rion University Hospital University of Patras, 26504 Patras, Greece

Abstract

Introduction: Knee arthrodesis is a limb salvage intervention for persistent periprosthetic joint infection (PJI) when revision total knee arthroplasty fails. Conventional arthrodesis techniques are associated with the increased rate of complications, especially in patients with extensive bone loss and extensor tendon deficiency. Methods: Eight patients with a modular silver-coated arthrodesis implant after failed exchange arthroplasty for infection, were retrospectively reviewed. All patients had significant bone loss, while 5 displayed extensor tendon deficiency. Survivorship, complications, leg length discrepancy, median Visual Analogue Scale (VAS) and Oxford Knee score (OKS) were evaluated. Results: The median follow up was 32 months (range 24–59 months). The survivorship rate of the prosthesis was 86% during the minimum time of follow up of 24 months. In one patient recurrence of the infection was observed and above-knee amputation was performed. The median postoperative leg length discrepancy was 2.07 ± 0.67 cm. Patients were able to ambulate with mild or no pain. The median VAS and OKS was 2.14 ± 0.9 and 34.7 ± 9.3, respectively. Conclusions: The results of our study demonstrated that knee arthrodesis with a silver coated arthrodesis implant, performed for persistent PJI in patients with significant bone loss and extensor tendon deficit, provided a stable construct, allowed eradication of infection and was associated with good functional outcome.

Publisher

MDPI AG

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3