Is the Pre-Shaping of an Orbital Implant on a Patient-Specific 3D-Printed Model Advantageous Compared to Conventional Free-Hand Shaping? A Systematic Review and Meta-Analysis

Author:

Singh Ashutosh Kumar1,Khanal Nikita2,Chaulagain Rajib3ORCID,Sharma Neha45ORCID,Thieringer Florian M.45ORCID

Affiliation:

1. Department of Oral and Maxillofacial Surgery, Tribhuvan University Teaching Hospital, Institute of Medicine, Kathmandu 44600, Nepal

2. Department of Population Health Sciences, University of Bristol, Bristol BS8 1QU, UK

3. Department of Oral Biology, Chitwan Medical College, Bharatpur 44200, Nepal

4. Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland

5. Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Hegenheimermattweg 167C, CH-4123 Allschwil, Switzerland

Abstract

This study aimed to perform a systematic review and meta-analysis to compare pre-shaped implants on a patient-specific 3D-printed (3DP) model to manual free-hand shaping (MFS) for orbital wall reconstruction. The PRISMA protocol was followed in this study, and the review was registered in the PROSPERO database (CRD42021261594). A search was conducted in MEDLINE (PubMed), Embase, Cochrane Library, Clinicaltrials.gov, Google Scholar, and the grey literature. Ten articles were included, and six outcomes were analyzed. In total, 281 patients were in the 3DP group and 283 were in the MFS group. The studies had an overall high risk of bias. 3DP models resulted in a better accuracy of fit, anatomical angle reproduction, and defect area coverage. The correction of orbital volume was also superior with statistical significance. There was a higher percentage of the correction of enophthalmos and diplopia in the 3DP group. Intraoperative bleeding and hospital stay were reduced in the 3DP group. The meta-analysis of operative time showed a reduction in the average operative time by 23.58 min (95% CI: −43.98 to −3.19), which was statistically significant (t(6) = −2.8299, p = 0.0300). The 3DP models appear advantageous for an accurate orbital wall reconstruction, with fewer complications than those for conventional free-hand-shaped implants.

Publisher

MDPI AG

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献