Reconstruction of Preclinical PET Images via Chebyshev Polynomial Approximation of the Sinogram

Author:

Protonotarios Nicholas E.ORCID,Fokas Athanassios S.ORCID,Vrachliotis Alexandros,Marinakis Vangelis,Dikaios NikolaosORCID,Kastis George A.ORCID

Abstract

Over the last decades, there has been an increasing interest in dedicated preclinical imaging modalities for research in biomedicine. Especially in the case of positron emission tomography (PET), reconstructed images provide useful information of the morphology and function of an internal organ. PET data, stored as sinograms, involve the Radon transform of the image under investigation. The analytical approach to PET image reconstruction incorporates the derivative of the Hilbert transform of the sinogram. In this direction, in the present work we present a novel numerical algorithm for the inversion of the Radon transform based on Chebyshev polynomials of the first kind. By employing these polynomials, the computation of the derivative of the Hilbert transform of the sinogram is significantly simplified. Extending the mathematical setting of previous research based on Chebyshev polynomials, we are able to efficiently apply our new Chebyshev inversion scheme for the case of analytic preclinical PET image reconstruction. We evaluated our reconstruction algorithm on projection data from a small-animal image quality (IQ) simulated phantom study, in accordance with the NEMA NU 4-2008 standards protocol. In particular, we quantified our reconstructions via the image quality metrics of percentage standard deviation, recovery coefficient, and spill-over ratio. The projection data employed were acquired for three different Poisson noise levels: 100% (NL1), 50% (NL2), and 20% (NL3) of the total counts, respectively. In the uniform region of the IQ phantom, Chebyshev reconstructions were consistently improved over filtered backprojection (FBP), in terms of percentage standard deviation (up to 29% lower, depending on the noise level). For all rods, we measured the contrast-to-noise-ratio, indicating an improvement of up to 68% depending on the noise level. In order to compare our reconstruction method with FBP, at equal noise levels, plots of recovery coefficient and spill-over ratio as functions of the percentage standard deviation were generated, after smoothing the NL3 reconstructions with three different Gaussian filters. When post-smoothing was applied, Chebyshev demonstrated recovery coefficient values up to 14% and 42% higher, for rods 1–3 mm and 4–5 mm, respectively, compared to FBP, depending on the smoothing sigma values. Our results indicate that our Chebyshev-based analytic reconstruction method may provide PET reconstructions that are comparable to FBP, thus yielding a good alternative to standard analytic preclinical PET reconstruction methods.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3