Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation?

Author:

Fania Chiara,Bagnati Marco,Albertario Marina,Ferraris Carlotta,Lamonaca Marta,Dianzani Umberto

Abstract

The analysis of immunosuppressive drugs allows the physician to monitor, and eventually correct, immunosuppressive therapy. The panel of molecules under evaluation includes cyclosporine A (CsA), tacrolimus, sirolimus, and everolimus. Initially, assays were performed by immunometric methods, but in the past few years this methodology has been largely superseded by a more accurate and specific technique, liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), which is now considered the “gold standard” for immunosuppressant analysis. Both LC-MS/MS and often also immunoassays require a preanalytical manual sample preparation, which involves time-consuming sequential operations whose traceability is often hampered and adds up to the probability of gross errors. The aim of this work was to compare an “open” LC-MS/MS with a fully automated system, consisting of LC instrumentation combined with a triple quadrupole MS, named Thermo ScientificTM CascadionTM SM Clinical Analyzer (Cascadion). Such automated systems suit the requirements of the reference method and are designed to completely eliminate all of the manual procedures. More than 2000 immunosuppressant samples were analyzed both with the open LC-MS/MS and with Cascadion. Statistics allowed the evaluation of linearity, intra- and inter-assay CV%, bias %, limit of detection and of quantitation, and Passing–Bablok and Bland–Altman plots. Results indicated a good correlation between the two methods. In both cases, methods confirmed their suitability for diagnostic settings. Cascadion could provide support when the presence of specialized personnel is lacking, and/or when great productivity and continuous workflow are required.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Automated LC-MS/MS: Ready for the clinical routine Laboratory?;Journal of Mass Spectrometry and Advances in the Clinical Lab;2023-11

2. Analytical Concordance of Total Vitamin D on a Fully Automated Random-Access LC–MS/MS Platform;The Journal of Applied Laboratory Medicine;2023-07-20

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3