The Value of Aortic Volume and Intraluminal Thrombus Quantification for Predicting Aortic Events after Endovascular Thoracic Aneurysm Repair

Author:

De Masi Mariangela1ORCID,Guivier-Curien Carine2ORCID,Cortaredona Sébastien34ORCID,Omnes Virgile1,Bal Laurence1ORCID,Muselier Baptiste5,Bartoli Axel5,Gaudry Marine1,Piquet Philippe1,Deplano Valérie2

Affiliation:

1. Timone Aortic Center, Department of Vascular Surgery, APHM, Timone Hospital, 13005 Marseille, France

2. CNRS, École Centrale Marseille, IRPHE UMR 7342, Aix-Marseille University, 13384 Marseille, France

3. IRD, AP-HM, SSA, VITROME, Aix-Marseille University, 13009 Marseille, France

4. IHU-Méditerranée Infection, 13385 Marseille, France

5. Department of Radiology, APHM, Timone Hospital, 13005 Marseille, France

Abstract

Objectives: To assess the ability of the aortic aneurysm volume (AAV), aneurysmal lumen volume (ALV), and aneurysmal thrombus volume (ATV) to predict the need for aortic reintervention when using the maximal aortic diameter as a reference. Methods: This monocentric retrospective study included 31 consecutive patients who underwent successful thoracic endovascular aortic repair (TEVAR) to treat an atheromatous thoracic aortic aneurysm. All patients underwent clinical and computed tomography angiography (CTA) for 3 years after TEVAR. The patients were categorized into group 0 if no aortic reintervention was required during the follow-up period and categorized into group 1 if they experienced a type I or III endoleak or aneurysm diameter increase requiring intervention. The maximum aneurysm sac diameter and the AAV, ALV, and ATV were calculated using CTA images obtained preoperatively (T0) and at 6–12 months (T1), 24 months (T2), and 36 months (T3) postoperatively, and their changes over time were analyzed. Correlations between diameter and changes in AAV, ALV, and ATV were assessed, and the association between diameter and volume changes and reintervetion was examined. The cutoff values for predicting the need for reintervention was determined using a receiver operating characteristic (ROC) curve. The accuracy of volume change versus diameter change for predicting the need for reintervention was analyzed. Results: There were no significant differences in terms of the mean aneurysm diameter or AAV, ALV or ATV between the groups at preoperative CTA or after one year of follow-up imaging. The mean ATV was higher in group 1 than in group 0 at 2 years (187.6 ± 86.3 mL vs. 114.7 ± 64.7 mL; p = 0.057) and after 3 years (195.0 ± 86.7 mL vs. 82.1 ± 39.9 mL; p = 0.013). The maximal diameter was greater in group 1 than in group 0 at 3 years (67.3 ± 9.5 mm vs. 55.3 ± 12.6 mm; p = 0.044). The rate of AAV change between T0 and T1 was significantly higher in group 1 (7 ± 4.5%) than in group 0 (−6 ± 6.8%; p < 0.001). The rate of ATV change between T1-T3 was significantly higher in group 1 than in group 0 (34 ± 40.9% vs. −13 ± 14.4% (p = 0.041)); similar results were observed for the rate of ATV change between T2 and T3 (27 ± 50.1% for group 1 vs. −8 ± 49.5% in group 0 (p < 0.001)). According to our multivariate analysis, the annual growth rate for AAV between T0 and T1 was the only independent factor that was significantly associated with aortic reintervention (area under the curve (AUC) = 0.84, OR = 1.57, p = 0.025; optimal cutoff +0.4%). An increase in the annual growth rate of the ATV between T0 and T3 was independently associated with the need for aortic reintervention (area under the curve (AUC) = 0.90, OR = 1.11, p = 0.0347; optimal cutoff +10.1%). Conclusions: Aortic volume analysis can predict the need for aortic reintervention more accurately and earlier than maximal aortic diameter.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3