Appropriate Data Quality Checks Improve the Reliability of Values Predicted from Milk Mid-Infrared Spectra

Author:

Zhang Lei,Li Chunfang,Dehareng FrédéricORCID,Grelet ClémentORCID,Colinet Frédéric,Gengler NicolasORCID,Brostaux YvesORCID,Soyeurt HélèneORCID

Abstract

The use of abnormal milk mid-infrared (MIR) spectrum strongly affects prediction quality, even if the prediction equations used are accurate. So, this record must be detected after or before the prediction process to avoid erroneous spectral extrapolation or the use of poor-quality spectral data by dairy herd improvement (DHI) organizations. For financial or practical reasons, adapting the quality protocol currently used to improve the accuracy of fat and protein contents is unfeasible. This study proposed three different statistical methods that would be easy to implement by DHI organizations to solve this issue: the deletion of 1% of the extreme high and low predictive values (M1), the deletion of records based on the Global-H (GH) distance (M2), and the deletion of records based on the absolute fat residual value (M3). Additionally, the combinations of these three methods were investigated. A total of 346,818 milk samples were analyzed by MIR spectrometry to predict the contents of fat, protein, and fatty acids. Then, the same traits were also predicted externally using their corresponded standardized MIR spectra. The interest in cleaning procedures was assessed by estimating the root mean square differences (RMSDs) between those internal and external predicted phenotypes. All methods allowed for a decrease in the RMSD, with a gain ranging from 0.32% to 41.39%. Based on the obtained results, the “M1 and M2” combination should be preferred to be more parsimonious in the data loss, as it had the higher ratio of RMSD gain to data loss. This method deleted the records based on the 2% extreme predictions and a GH threshold set at 5. However, to ensure the lowest RMSD, the “M2 or M3” combination, considering a GH threshold of 5 and an absolute fat residual difference set at 0.30 g/dL of milk, was the most relevant. Both combinations involved M2 confirming the high interest of calculating the GH distance for all samples to predict. However, if it is impossible to estimate the GH distance due to a lack of relevant information to compute this statistical parameter, the obtained results recommended the use of M1 combined with M3. The limitation used in M3 must be adapted by the DHI, as this will depend on the spectral data and the equation used. The methodology proposed in this study can be generalized for other MIR-based phenotypes.

Publisher

MDPI AG

Subject

General Veterinary,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3