Abstract
Microwave radiometers can be used in human tissue temperature measurement scenarios due to the advantages of non-destructive and non-contact temperature measurement. However, their accuracy often cannot meet the needs of practical applications. In this paper, a Ku-Band high-precision blackbody calibration target is designed to provide calibration for microwave radiometers and meet the requirements of a high temperature-measurement accuracy and high temperature-measurement resolution. From a practical application point of view, the blackbody calibration target needs to have the characteristics of high emissivity and high temperature uniformity. However, previous studies on blackbody calibration targets often focused on the scattering characteristics or temperature uniformity of the calibration target separately, and thus lack a comprehensive consideration of the two characteristics. In this paper, the electromagnetic scattering model and the temperature-distribution model of the calibration target are established through the multi-physical simulation combined with the Finite Element Method. Then, according to the simulation results of the two characteristic models, the structural parameters and composition of the coated cone array are continuously optimized. In addition, to achieve high-precision temperature control of the blackbody calibration target, this paper studies three PID controller parameter self-tuning algorithms, namely, BP-PID, PSO-PID and Fuzzy-PID for the optimal parameter tuning problem of traditional PID algorithms and determines the optimal temperature-control algorithm by comparing the performance of heating and cooling processes. Then, the blackbody calibration target is processed and manufactured. The arch test system is used to validate the reflectance of the calibration target, the emissivity is calculated indirectly, and the temperature-distribution uniformity of the temperature-control panel of the calibration target is tested by a multi-point distribution method. Finally, the uncertainty of the brightness temperature of the blackbody calibration target is analyzed.
Funder
the Chinese Academy of Sciences
the National Key Research and Development Program of China
the National Natural Science Foundation of China
the Beijing Municipal Commission of Education
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering
Reference31 articles.
1. He, F. (2015). Study of Nondestructive Retrieval Method for the Measurement of Human Internal Temperature by Microwave. [Master’s Thesis, HUST].
2. Park, W., and Jeong, J. (2017). Total Power Radiometer for Medical Sensor Applications Using Matched and Mismatched Noise Sources. Sensors, 17.
3. Yoon, H., Song, K., Lee, U., and Choi, S. (2012, January 24). Microwave thermal radiation effects on skin tissues. Proceedings of the SPIE 8548, Nanosystems in Engineering and Medicine, Incheon, Republic of Korea.
4. Toward wearable wireless thermometers for internal body temperature measurements;Popovic;IEEE Commun. Mag.,2014
5. Sun, Z., Liu, J., Zhang, K., Wang, Y., Xu, D., and Xu, J. (2021, January 12–14). Research on modeling and inversion of human skin tissue based on multi-band microwave radiometer. Proceedings of the 2021 2nd Asia Symposium on Signal Processing, Beijing, China.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献