Biomechanical Performance of a Novel Implant Design in Simulated Extraction Sites and Sinuslift Procedures

Author:

Klär Virgilia1ORCID,Zimmerer Rüdiger2,Schulz Annika1,Lethaus Bernd2ORCID

Affiliation:

1. Department of Prosthodontics, Saarland University, Kirrberger Strasse 100, 66421 Homburg/Saar, Germany

2. Department of Oral and Maxillofacial Surgery, University of Leipzig, Liebigstrasse 12, 04103 Leipzig, Germany

Abstract

With increasing experience and in an attempt to shorten overall treatment times, implant placement in combination with tooth extractions and sinus lift procedures has become popular. In both cases, primary stability has to be achieved by either engaging apical and oral regions of trabecular bone or by engaging residual host bone beneath the sinus cavity. Extraction sites were formed by pressing a root analog into homogeneous low density polyurethane foam which was used as bone surrogate while a 3 mm thick sheet of medium density foam was used for mimicking a sinus lift situation. Two types (n = 10) of bone level implants with a conventional tapered design and a cervical back taper (NobelActive; control) and a novel design characterized by a shift in core diameter and thread geometry (AlfaGate; test) were placed in these models following conventional osteotomy preparation. Insertion torque was measured using a surgical motor and primary stability was determined by resonance frequency analysis. Statistical analysis was based on Welch two sample t tests with the level of significance set at α = 0.05. In sinuslifting, NobelActive implants required significantly higher insertion torques as compared to AlfaGate (p = 0.000) but did not achieve greater implant stability (p = 0.076). In extraction sites, AlfaGate implants showed both, significantly higher insertion torques (p = 0.004) and significantly greater implant stability (p = 0.000). The novel implant design allowed for greater primary stability when being placed in simulated extraction sockets and sinuslift situations. While in extraction sockets the position of condensing threads in combination with an increase in core diameter is beneficial, the deep cervical threads of the novel implant lead to superior performance in sinuslift situations.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3