Abstract

Response surface models (RSMs) are a new trend in modern anesthesia. RSMs have demonstrated significant applicability in the field of anesthesia. However, the comparative analysis between RSMs and logistic regression (LR) in different surgeries remains relatively limited in the current literature. We hypothesized that using a total intravenous anesthesia (TIVA) technique with the response surface model (RSM) and logistic regression (LR) would predict the emergence from anesthesia in patients undergoing video-assisted thoracotomy surgery (VATS). This study aimed to prove that LR, like the RSM, can be used to improve patient safety and achieve enhanced recovery after surgery (ERAS). This was a prospective, observational study with data reanalysis. Twenty-nine patients (American Society of Anesthesiologists (ASA) class II and III) who underwent VATS for elective pulmonary or mediastinal surgery under TIVA were enrolled. We monitored the emergence from anesthesia, and the precise time point of regained response (RR) was noted. The influence of varying concentrations was examined and incorporated into both the RSM and LR. The receiver operating characteristic (ROC) curve area for Greco and LR models was 0.979 (confidence interval: 0.987 to 0.990) and 0.989 (confidence interval: 0.989 to 0.990), respectively. The two models had no significant differences in predicting the probability of regaining response. In conclusion, the LR model was effective and can be applied to patients undergoing VATS or other procedures of similar modalities. Furthermore, the RSM is significantly more sophisticated and has an accuracy similar to that of the LR model; however, the LR model is more accessible. Therefore, the LR model is a simpler tool for predicting arousal in patients undergoing VATS under TIVA with Remifentanil and Propofol.

Funder

Ministry of Science and Technology, Taiwan

Anesthesiology Research and Development Foundation

Publisher

MDPI AG

Subject

Drug Discovery,Pharmaceutical Science,Molecular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3