Research on Packaging Reliability and Quality Factor Degradation Model for Wafer-Level Vacuum Sealing MEMS Gyroscopes
-
Published:2023-10-20
Issue:10
Volume:14
Page:1956
-
ISSN:2072-666X
-
Container-title:Micromachines
-
language:en
-
Short-container-title:Micromachines
Author:
Xu Yingyu12, Liu Shuibin1, He Chunhua1ORCID, Wu Heng1ORCID, Cheng Lianglun1, Huang Qinwen2, Yan Guizhen3
Affiliation:
1. School of Computer, Guangdong University of Technology, Guangzhou 510006, China 2. Science and Technology on Reliability Physics and Application Technology of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 510006, China 3. National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, Beijing 100871, China
Abstract
MEMS gyroscopes are widely applied in consumer electronics, aerospace, missile guidance, and other fields. Reliable packaging is the foundation for ensuring the survivability and performance of the sensor in harsh environments, but gas leakage models of wafer-level MEMS gyroscopes are rarely reported. This paper proposes a gas leakage model for evaluating the packaging reliability of wafer-level MEMS gyroscopes. Based on thermodynamics and hydromechanics, the relationships between the quality factor, gas molecule number, and a quality factor degradation model are derived. The mechanism of the effect of gas leakage on the quality factor is explored at wafer-level packaging. The experimental results show that the reciprocal of the quality factor is exponentially related to gas leakage time, which is in accordance with the theoretical analysis. The coefficients of determination (R2) are all greater than 0.95 by fitting the curves in Matlab R2022b. The stable values of the quality factor for drive mode and sense mode are predicted to be 6609.4 and 1205.1, respectively, and the average degradation characteristic time is 435.84 h. The gas leakage time is at least eight times the average characteristic time, namely 3486.72 h, before a stable condition is achieved in the packaging chamber of the MEMS gyroscopes.
Funder
National Natural Science Foundation of China Natural Science Foundation of Guangdong Province Basic and Applied Basic Research Project of Guangzhou Basic Research Program
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering
Reference33 articles.
1. Xu, P., Si, C., He, Y., Wei, Z., Jia, L., Han, G., Ning, J., and Yang, F. (2021). A Novel High-Q Dual-Mass MEMS Tuning Fork Gyroscope Based on 3D Wafer-Level Packaging. Sensors, 21. 2. Du, G., Dong, X., Huang, X., Su, W., and Zhang, P. (2022). Reliability Evaluation Based on Mathematical Degradation Model for Vacuum Packaged MEMS Sensor. Micromachines, 13. 3. Wafer level packaging of MEMS;Esashi;J. Micromech. Microeng.,2008 4. Gerrard, D.D., Ahn, C.H., Flader, I.B., Chen, Y., Ng, E.J., Yang, Y., and Kenny, T.W. (2016, January 24–28). Q-factor optimization in disk resonator gyroscopes via geometric parameterization. Proceedings of the 2016 IEEE 29th International Conference on Micro Electro Mechanical Systems (MEMS), Shanghai, China. 5. Jia, L., Han, G., Wei, Z., Si, C., Ning, J., Yang, F., and Han, W. (2022). A Novel Packaged Ultra-High Q Silicon MEMS Butterfly Vibratory Gyroscope. Micromachines, 13.
|
|