Development and Validation of Novel HPLC Methods for Quantitative Determination of Vitamin D3 in Tablet Dosage Form

Author:

Gohar Muhammad Saqib1,Rahman Taj Ur1,Bahadur Ali2ORCID,Ali Ashraf3ORCID,Alharthi Sarah45ORCID,Al-Shaalan Nora Hamad6

Affiliation:

1. Department of Chemistry, Mohi-Ud-Din Islamic University, Nerian Sharif, Azad Jammu & Kashmir 12080, Pakistan

2. Department of Chemistry, School of Natural Sciences (SNS), National University of Science and Technology (NUST), H-12, Islamabad 46000, Pakistan

3. School of Chemistry & Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China

4. Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia

5. Research Center of Basic Sciences, Engineering and High Altitude, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia

6. Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia

Abstract

In the present work, an efficient isocratic HPLC method was developed for the precise and accurate estimation of vitamin D3 in tablet form. The chromatographic conditions comprised an L3 silica column (5 µm in particle size, 4.6 mm × 250 mm) with a mobile phase n-hexane/ethyl acetate (85:15 v/v) with a flow rate of 2.0 mL/min and a detection wavelength of 292 nm. The new methodology was validated for accuracy, precision, specificity, robustness, and quantification limits according to an official monograph of USP/BP and ICH guidelines. The peak areas of the six replicates of the homogeneous sample were recorded. The mean value obtained was 67,301, and the relative standard deviation (RSD) was 0.1741. The linearity and range were in the acceptable bounds, i.e., 0.999, which was calculated using regression line analysis. The results show that the method is truly acceptable as the RSD, as the flow rate was 0.81%, while for the mobile phase composition, it was 0.72%, which lies in the acceptable range. The limit of detection (LOD) and the limit of quantification (LOQ) values were 0.0539 µg/mL and 0.1633 µg/mL, respectively. The % RSD of the intra and inter-day precision of the method was deemed acceptable according to the international commission for harmonization guidelines. The developed method has potential to be used for the detection and quantification of vitamin D3 during routine analysis for tablets in dosage form.

Funder

Higher Education Commission (HEC), Pakistan

Publisher

MDPI AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3