Abstract
The local structure, turbulence, and heat transfer in a flat ribbed duct during the evaporation of water droplets in a gas flow were studied numerically using the Eulerian approach. The structure of a turbulent two-phase flow underwent significant changes in comparison with a two-phase flow in a flat duct without ribs. The maximum value of gas-phase turbulence was obtained in the region of the downstream rib, and it was almost twice as high as the value of the kinetic energy of the turbulence between the ribs. Finely dispersed droplets with small Stokes numbers penetrated well into the region of flow separation and were observed over the duct cross section; they could leave the region between the ribs due to their low inertia. Large inertial droplets with large Stokes numbers were present only in the mixing layer and the flow core, and they accumulated close to the duct ribbed wall in the flow towards the downstream rib. An addition of evaporating water droplets caused a significant enhancement in the heat transfer (up to 2.5 times) in comparison with a single-phase flow in a ribbed channel.
Funder
Ministry of Science and Higher Education of the Russian Federation
State contract with IT SB RAS
Subject
Water Science and Technology,Aquatic Science,Geography, Planning and Development,Biochemistry
Reference42 articles.
1. Webb, R.L., and Kim, N.N. (2005). Principles of Enhanced Heat Transfer, Taylor & Francis. [2nd ed.].
2. Han, J.C., Dutta, S., and Ekkad, S. (2012). Gas Turbine Heat Transfer and Cooling Technology, CRC Press. [2nd ed.].
3. Kalinin, E.K., Dreitser, G.A., and Yarkho, S.A. (1990). Enhancement of Heat Transfer in Channels, Mashinostroenie. (In Russian).
4. Terekhov, V., Dyachenko, A., Smulsky, Y., Bogatko, T., and Yarygina, N. (2022). Heat Transfer in Subsonic Separated Flows, Springer.
5. An investigation of heat transfer and friction for rib-roughened surfaces;Int. J. Heat Mass Transf.,1978
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献